Study design for microgravity human physiology experiments.

Aviat Space Environ Med

Microgravity Life Sciences Research Unit, University of British Columbia, University Hospital, Vancouver, Canada.

Published: February 1993

In some areas of research, such as microgravity life sciences, both the number of subjects and the opportunity for repeated observation under experimental conditions are limited. Small N study designs are appropriate for these situations since they require few subjects and few observations in the experimental condition. Small N studies compare treatment conditions separately for each subject so that between-subject variability does not obscure treatment effects. Multiple observations are collected for each individual in the baseline condition to ensure a stable reference point for comparison with the smaller number of observations collected under the experimental conditions. Individual differences can be overlooked in large N studies, but in small N studies the focus is on the individual, and differences observed between particular individuals can be suggestive of underlying causal processes. We present a step-by-step approach to designing and conducting a small N study.

Download full-text PDF

Source

Publication Analysis

Top Keywords

experimental conditions
8
small study
8
small studies
8
observations collected
8
individual differences
8
study design
4
design microgravity
4
microgravity human
4
human physiology
4
physiology experiments
4

Similar Publications

Background And Objectives: Mitochondrial disorders are multiorgan disorders resulting in significant morbidity and mortality. We aimed to characterize death-associated factors in an international cohort of deceased individuals with mitochondrial disorders.

Methods: This cross-sectional multicenter observational study used data provided by 26 mitochondrial disease centers from 8 countries from January 2022 to March 2023.

View Article and Find Full Text PDF

A Quantitative First Passage Time Model for Tubular Microfluidic Immunoassays.

ACS Sens

January 2025

Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.

Solid-phase immunosorbent reactions, such as ELISA, are widely used for detecting, identifying, and quantifying protein markers. However, traditional centimeter scale well-based immunoreactors suffer from low surface-to-volume (S/V) ratios, leading to large sample consumption and a long assay time. Microfluidic technologies, particularly tubular microfluidic immunoreactors, have emerged as promising alternatives due to their high S/V ratios.

View Article and Find Full Text PDF

Extremal structures with embedded prefailure indicators.

Proc Natl Acad Sci U S A

February 2025

Department of Construction Sciences, Lund University, Lund SE-22100, Sweden.

Preemptive identification of potential failure under loading of engineering structures is a critical challenge. Our study presents an innovative approach to design built-in prefailure indicators within multiscale structural designs with optimized load carrying capabilities utilizing the design freedom of topology optimization. The indicators are engineered to visibly signal load conditions approaching the global critical buckling load at predefined locations.

View Article and Find Full Text PDF

Background: Ankle sprain is a common clinical disease, which has the highest incidence rate among joint and ligament injuries. And acute ankle sprains can easily develop into chronic ankle instability, thereby increasing the difficulty of treatment. The current clinical guidelines for post-acute ankle sprains are still controversial.

View Article and Find Full Text PDF

In this paper, we present a new computational framework for the simulation of airway resistance, the fraction of exhaled nitric oxide, and the diffusion capacity for nitric oxide in healthy and unhealthy lungs. Our approach is firstly based on a realistic representation of the geometry of healthy lungs as a function of body mass, which compares well with data from the literature, particularly in terms of lung volume and alveolar surface area. The original way in which this geometry is created, including an individual definition of the airways in the first seven generations of the lungs, makes it possible to consider the heterogeneous nature of the lungs in terms of perfusion and ventilation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!