Study Objective: To compare an experimental algorithm with standard advanced cardiac life support in a swine model of out-of-hospital cardiac arrest.

Design: Randomized, controlled experimental trial. SETTING/TYPE OF PARTICIPANT: Animal laboratory using swine.

Interventions: Eighteen swine (17.8 to 23.7 kg) were sedated, intubated, anesthetized, and instrumented for monitoring of arterial and central venous pressures and ECG. Ventricular fibrillation was induced using a bipolar pacing catheter. Animals were randomized to treatment with the experimental algorithm or standard advanced cardiac life support therapy after eight minutes of untreated ventricular fibrillation. The experimental algorithm consisted of starting CPR; giving high-dose epinephrine (0.20 mg/kg), lidocaine (1.0 mg/kg), bretylium (5.0 mg/kg), and propranolol (0.5 to 1.0 mg) by peripheral IV; hyperventilating (20 to 25 breaths per minute); and delaying countershock (5 J/kg) 60 seconds after completion of drug delivery. Data were analyzed with the Student's t-test and Fisher's exact test.

Measurements And Main Results: Outcome variables were arterial and central venous pressures, return of spontaneous circulation, and one-hour survival. Hemodynamics were not different between groups during CPR. Return of spontaneous circulation occurred in seven of nine swine (77%) in the experimental algorithm group versus two of nine swine (22%) in the advanced cardiac life support group (P = .057). Four of nine swine (44%) in the experimental algorithm group survived to one hour versus none of the animals in the advanced cardiac life support group (P = .041).

Conclusion: In this swine model of out-of-hospital cardiac arrest, animals treated with an experimental algorithm had a significant improvement in one-hour survival compared with those treated with advanced cardiac life support.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0196-0644(05)80211-2DOI Listing

Publication Analysis

Top Keywords

experimental algorithm
28
advanced cardiac
24
cardiac life
24
life support
24
standard advanced
12
swine model
12
model out-of-hospital
12
out-of-hospital cardiac
12
cardiac
9
experimental
8

Similar Publications

Rapid validation of newly predicted materials through autonomous synthesis requires real-time adaptive control methods that exploit physics knowledge, a capability that is lacking in most systems. Here, we demonstrate an approach to enable real-time control of thin film synthesis by combining optical diagnostics with a Bayesian state estimation method. We developed a physical model for film growth and applied the direct filter (DF) method for real-time estimation of nucleation and growth rates during pulsed laser deposition (PLD).

View Article and Find Full Text PDF

Predictions of student performance are important to the education system as a whole, helping students to know how their learning is changing and adjusting teachers' and school policymakers' plans for their future growth. However, selecting meaningful features from the huge amount of educational data is challenging, so the dimensionality of student achievement features needs to be reduced. Based on this motivation, this paper proposes an improved Binary Snake Optimizer (MBSO) as a wrapped feature selection model, taking the Mat and Por student achievement data in the UCI database as an example, and comparing the MBSO feature selection model with other feature methods, the MBSO is able to select features with strong correlation to the students and the average number of student features selected reaches a minimum of 7.

View Article and Find Full Text PDF

A key contribution to X-ray dark-field (XDF) contrast is the diffusion of X-rays by sample structures smaller than the imaging system's spatial resolution; this is related to position-dependent small-angle X-ray scattering. However, some experimental XDF techniques have reported that XDF contrast is also generated by resolvable sample edges. Speckle-based X-ray imaging (SBXI) extracts the XDF by analyzing sample-imposed changes to a reference speckle pattern's visibility.

View Article and Find Full Text PDF

The misalignment between the geometric and optical axes, combined with rotational asymmetry, poses significant challenges for achieving high-accuracy measurement of the off-axis aspheric mirror during the fabrication and polishing processes. To address this issue, this paper presents a method based on stereo deflectometry for measuring the figure of the off-axis aspheric mirror. In this method, point cloud of the off-axis aspheric mirror is first obtained using stereo deflectometry.

View Article and Find Full Text PDF

This paper presents RecNet, an innovative convolutional neural network designed for reconstructing cecond harmonic generation frequency-resolved optical gating (SHG-FROG) traces. Unlike conventional approaches, RecNet incorporates noiseless sample constraints through a domain knowledge embedded loss function, enhancing the network's robustness to noise and interpretability. The encoder-decoder architecture is intentionally selected to match the dimensions of the trace diagram with intermediate representations, facilitating the effective application of these constraints.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!