Background: The mechanisms of action of exercise-simulating and vasodilator stressors support their combination with imaging techniques that evaluate left ventricular function and perfusion, respectively. However, reported accuracies of either pharmacological stress together with two-dimensional echocardiography (2DE) or single photon emission computed tomography (SPECT) of myocardial perfusion are similar. The purpose of this study was to establish the optimal stress for each imaging technique by comparing the results of digitized 2DE and 99mTc-methoxyisobutyl isonitrile (MIBI) SPECT using both dobutamine and adenosine stresses in the same patients and conditions.

Methods And Results: Ninety-seven consecutive patients without evidence of previous infarction undergoing coronary angiography for clinical indications were studied prospectively. Dobutamine was infused during clinical, ECG, and echocardiographic monitoring in dose increments from 5 to 40 micrograms.kg-1.min-1. Adenosine was infused under the same conditions in doses of 0.10, 0.14, and 0.18 mg.kg-1.min-1. For each protocol, the end points were achievement of peak dose, development of severe ischemia, or intolerable side effects. At peak stress, 20 mCi of MIBI was injected, and SPECT imaging was performed 2 hours later; abnormal poststress images were compared with resting SPECT: Digitized 2DE images were compared qualitatively before, during, and after stress in a cine-loop display. Significant coronary disease (n = 59 patients) was defined by the quantification of > 50% stenosis in a major epicardial vessel. The sensitivity of adenosine 2DE was 58%, less than those of adenosine MIBI (86%, p = 0.001), dobutamine 2DE (85%, p = 0.001), and dobutamine MIBI (80%, p = 0.01). Their respective specificities were 87%, 71%, 82%, and 74% (p = NS). The accuracy of adenosine 2DE was 69%, compared with 80% for adenosine MIBI (p < 0.001), 84% for dobutamine 2DE (p = 0.001), and 77% for dobutamine MIBI (p = 0.005); the latter three did not differ significantly in either sensitivity or accuracy.

Conclusions: This prospective, direct comparison of alternative pharmacological stresses in patients without myocardial infarction shows vasodilator stress scintigraphy and dobutamine stress echocardiography and scintigraphy to share equivalent levels of sensitivity. All three are significantly more sensitive than adenosine stress echocardiography. Dobutamine stress may be used for wall motion or perfusion imaging, but adenosine stress is best combined with perfusion scintigraphy.

Download full-text PDF

Source
http://dx.doi.org/10.1161/01.cir.87.2.345DOI Listing

Publication Analysis

Top Keywords

stress
10
dobutamine
9
adenosine
9
dobutamine adenosine
8
single photon
8
photon emission
8
emission computed
8
computed tomography
8
digitized 2de
8
stresses patients
8

Similar Publications

Rapid reduction of body size in populations responding to global warming suggests the involvement of temperature-dependent physiological adjustments during growth, such as mitochondrial alterations, in the efficiency of producing metabolic energy, a process that is poorly explored, especially in endotherms. Here, we examined the mitochondrial metabolism and proteomic profile of red blood cells in relation to body size and cellular energetics in nestling shearwaters (Calonectris diomedea) developing at different natural temperatures. We found that nestlings of warmer nests had lighter bodies and smaller beaks at fledging.

View Article and Find Full Text PDF

Parkinson's Disease (PD) is a neurodegenerative disorder characterized by the pro-gressive loss of dopaminergic neurons in the substantia nigra, leading to motor dysfunction and non-motor symptoms. Current treatments primarily offer symptomatic relief without halt-ing disease progression. This has driven the exploration of natural compounds with neuropro-tective properties.

View Article and Find Full Text PDF

Introduction: Chronic ischemic heart failure is a major global health issue despite advancements in therapy. Stem cell (SC) therapy has emerged as a potential treatment, but its effectiveness remains uncertain. This study aimed to systematically review and meta-analyze the current evidence on SC therapy's efficacy.

View Article and Find Full Text PDF

Body size declines are a common response to warming via both plasticity and evolution, but variable size responses have been observed for terrestrial ectotherms. We investigate how temperature-dependent development and growth rates in ectothermic organisms induce variation in size responses. Leveraging long-term data for six montane grasshopper species spanning 1,768-3 901 m, we detect size shifts since ~1960 that depend on elevation and species' seasonal timing.

View Article and Find Full Text PDF

As humans age, they experience deformity and a decrease in their bone strength, such brittleness in the bones ultimately lead to bone fracture. Magnetic field exposure combined with physical exercise may be useful in mitigating age-related bone loss by improving the canalicular fluid motion within the bone's lacuno-canalicular system (LCS). Nevertheless, an adequate amount of fluid induced shear stress is necessary for the bone mechano-transduction and solute transport in the case of brittle bone diseases.

View Article and Find Full Text PDF