As part of a clinical investigation evaluating the efficacy of intrapartum antigen detection for screening for heavy vaginal colonization with group B streptococci (GBS), we compared the performance of modified Bactigen and Directigen GBS latex particle agglutination (LPA) kits. Paired vaginal swabs obtained from women in labor were rapidly transported to the laboratory and used for culturing (both swabs) and LPA testing (one swab by each method). GBS growth was estimated semiquantitatively and further designated as light or heavy growth. Performance specifications for each method were determined by comparing LPA and culture results from the same swab. A total of 4,251 paired swabs were evaluated during the study period. The performance specifications for detecting GBS growth of any degree for Bactigen and Directigen, respectively, were as follows: sensitivity, 20 and 24%; specificity, 99 and 99%. The performance specifications for heavy colonization for Bactigen and Directigen, respectively, were as follows: sensitivity, 57 and 62%; specificity, 99 and 99%. Neither LPA kit was a sensitive indicator of vaginal colonization with GBS or neonatal infection.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC262625PMC
http://dx.doi.org/10.1128/jcm.31.1.78-82.1993DOI Listing

Publication Analysis

Top Keywords

bactigen directigen
12
performance specifications
12
vaginal colonization
8
gbs growth
8
directigen sensitivity
8
specificity 99%
8
gbs
5
comparison antigen
4
antigen assays
4
assays rapid
4

Similar Publications

Latex particle agglutination (LPA) testing for antigen to group B streptococcus (GBS) has been useful in the diagnosis of GBS sepsis in newborns. However, recent reports have demonstrated that the sensitivity of LPA assays may be as low as 27 to 54%. The purposes of the present study were to directly compare the abilities of four urine antigen assays to detect GBS antigen with clinical urine samples from neonates with GBS bacteremia and to evaluate the effect of the urine concentration on the sensitivities and specificities of these assays.

View Article and Find Full Text PDF

As part of a clinical investigation evaluating the efficacy of intrapartum antigen detection for screening for heavy vaginal colonization with group B streptococci (GBS), we compared the performance of modified Bactigen and Directigen GBS latex particle agglutination (LPA) kits. Paired vaginal swabs obtained from women in labor were rapidly transported to the laboratory and used for culturing (both swabs) and LPA testing (one swab by each method). GBS growth was estimated semiquantitatively and further designated as light or heavy growth.

View Article and Find Full Text PDF

Accurate rapid detection of maternal lower genital tract colonization with group B streptococci (GBS) in high-risk patients is essential for selective institution of intrapartum antibiotic treatment to reduce neonatal GBS infection. In this study, pure GBS isolates were used to evaluate five commercially available rapid tests in terms of speed, ease of use, and sensitivity. The products tested were Directigen, Equate, Bactigen, PathoDx, and Phadebact.

View Article and Find Full Text PDF

The validity of commercial latex agglutination kits for detection of Haemophilus influenzae type b and Streptococcus pneumoniae antigens in serum and urine specimens was studied. We tested serum and urine specimens from 44 patients with bacteremic pneumonia (23 S. pneumoniae, 13 H.

View Article and Find Full Text PDF

Three commercial latex agglutination kits (Bactigen, Wampole Laboratories, Cranbury, NJ; Directigen, Hynson, Westcott & Dunning, Baltimore, MD; Wellcogen, Wellcome Diagnostics, Dartford, England) used for the detection of bacterial polysaccharide antigens (Haemophilus influenzae type b, Streptococcus pneumoniae, and Neisseria meningitidis) were compared with counterimmunoelectrophoresis and Gram stain for the identification of systemic bacterial disease in children. Urine and (when available) cerebrospinal fluid specimens were saved for all patients. Positive blood or cerebrospinal fluid culture isolates included 36 with H.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!