Magnetic resonance imaging (MRI) was performed on 13 testes of 12 patients with testicular abnormalities. In all cases, scrotal palpation and initial clinical course had suggested malignant testicular tumors. The normal testes showed homogeneous intermediate signal intensity on T1-weighted images and high signal intensity on T2-weighted images such as the appearance of the corpus cavernosum penis. Ten patients proved to have testicular tumors. In eight of them, the tumors showed homogeneous intermediate signal intensity on T1-weighted images, while in the other two, these images showed heterogeneous signal intensity. In four patients, tumors were of homogeneous low signal intensity on T2-weighted images, while in the other six, these images showed heterogeneous signal intensity. The rate of correspondence about local staging of testicular tumor between MRI and pathological diagnosis was 70 percent. In three patients whose testes were undoubtedly malignant according to clinical findings and examination data, MRI enabled us to diagnose one case of testicular atrophy. However, MRI suggested benign disease in the other two patients; nevertheless, surgery was performed as indicated by the other findings.

Download full-text PDF

Source
http://dx.doi.org/10.5980/jpnjurol1989.84.1635DOI Listing

Publication Analysis

Top Keywords

signal intensity
24
testicular tumor
8
magnetic resonance
8
testicular tumors
8
homogeneous intermediate
8
intermediate signal
8
intensity t1-weighted
8
t1-weighted images
8
intensity t2-weighted
8
t2-weighted images
8

Similar Publications

Recent studies suggest that calcitonin gene-related peptide (CGRP) neurons in the parabrachial nucleus (PBN) represent aversive information and signal a general alarm to the forebrain. If CGRP neurons serve as a true general alarm, their activation would modulate both passive nad active defensive behaviors depending on the magnitude and context of the threat. However, most prior research has focused on the role of CGRP neurons in passive freezing responses, with limited exploration of their involvement in active defensive behaviors.

View Article and Find Full Text PDF

We have employed a triazine-based conjugated polymer network (CPN) for the selective detection of hypochlorite in a semi-aqueous environment. CPNs have been widely employed in gas capture, separation, and adsorption, but the fluorescent properties of CPNs possessing extensive π-conjugated systems tend to be unexplored. Herein, we report the photophysical properties of the CPN and investigate its sensing capability towards hypochlorite.

View Article and Find Full Text PDF

Background: Echocardiography is widely used to assess aortic stenosis (AS) but can yield inconsistent results, leading to uncertainty about AS severity and the need for further diagnostics. This retrospective study aimed to evaluate a novel echocardiography-based marker, the signal intensity coefficient (SIC), for its potential in accurately identifying and quantifying calcium in AS, enhancing noninvasive diagnostic methods.

Methods: Between May 2022 and October 2023, 112 cases of AS that were previously considered severe by echocardiography were retrospectively evaluated, as well as a group of 50 cases of mild or moderate AS, both at the Eastern Slovak Institute of Cardiovascular Diseases in Kosice, Slovakia.

View Article and Find Full Text PDF

Geologic records of tropical cyclones (TCs) in low-energy, back-barrier environments are established by identifying marine sediments via their allochthonous biogeochemical signal. These records have the potential to reconstruct TC intensity and frequency through time. However, modern analog studies are needed to understand which biogeochemical indicators of overwash sediments are best preserved and how post-depositional changes may affect their preservation.

View Article and Find Full Text PDF

Fiber-Optic Photoacoustic Gas Microprobe Based on Linear Spot-Type Multipass Cell.

Anal Chem

January 2025

School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, Liaoning 116024, China.

A linear spot-type multipass cell-enhanced fiber-optic photoacoustic gas microprobe is proposed. To further reduce the volume of the gas chamber and enhance the photoacoustic signal, we designed the cross section of the photoacoustic tube as a slit with a height of 10 mm and a width of 1.5 mm.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!