A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

IAEA-WHO cobalt-60 teletherapy dosimetry service using mailed LiF dosemeters. A survey of results obtaining during 1970-75. | LitMetric

The IAEA-WHO postal dose comparison service for cobalt-60 teletherapy dosimetry is an ongoing programme aimed at improving dosimetric accuracy in IAEA-WHO Member States. LiF dosemeters were irradiated under specified conditions in a water phantom at the participating radiotherapy centres and returned to the IAEA's Dosimetry Labotatory for evaluation. The participants filled in a data sheet giving numerical values of physical factors (such as per cent depth dose, tissue-air ratio, etc.) that they employed. Nearly 65% of the comparisons showed deviations within +/- 5%, a figure which is believed to represent the overall uncertainty of the method itself. Almost 10% of the measurements deviated more than +/- 15%. It appears that participants applying 'in phantom' output measurements have better control over the dose they administer. Many of the errors observed are due to the use of faulty values for the various physical factors employed, and to the fact that often a check of the output just before the irradiation of the LiF dosemeters was not carried out.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/22/1/003DOI Listing

Publication Analysis

Top Keywords

lif dosemeters
12
cobalt-60 teletherapy
8
teletherapy dosimetry
8
values physical
8
physical factors
8
iaea-who cobalt-60
4
dosimetry service
4
service mailed
4
mailed lif
4
dosemeters survey
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!