Angular velocity detection by head movements orthogonal to the plane of rotation.

Exp Brain Res

Department of Neurology, University Hospital, Zürich, Switzerland.

Published: October 1993

Sinusoidal oscillation of rhesus monkeys about a head-fixed, earth-horizontal axis while rotating at constant velocity about an earth-vertical axis generates a characteristic ocular nystagmus where the three-dimensional slow phase eye velocity is compensatory to the spatially and temporally changing head angular velocity vector. This includes the generation of a unidirectional nystagmus characterised by a "bias" slow phase velocity component, albeit of small gain (0.2-0.7), that persists for the duration of the combined two-axes stimulation and is compensatory to the constant velocity earth-vertical axis rotation. Specifically, there is a torsional bias velocity in supine position, a vertical bias velocity in ear down position and a horizontal bias velocity in upright position. Since the semicircular canals can not sense prolonged constant velocity rotation, the ocular bias velocity must be centrally constructed from canal afferent signals using head position information. Thus, optimal performance of the vestibular system as a three-dimensional rate sensor relies on afferent information from both the semicircular canals and the otolith organs.

Download full-text PDF

Source
http://dx.doi.org/10.1007/BF00229656DOI Listing

Publication Analysis

Top Keywords

bias velocity
16
constant velocity
12
velocity
10
angular velocity
8
velocity earth-vertical
8
earth-vertical axis
8
slow phase
8
semicircular canals
8
velocity detection
4
detection head
4

Similar Publications

The trajectory of crime: Integrating mouse-tracking into concealed memory detection.

Behav Res Methods

January 2025

Centre for Cognitive and Brain Sciences and Department of Psychology, University of Macau, Taipa, 999078, Macau, China.

The autobiographical implicit association test (aIAT) is an approach of memory detection that can be used to identify true autobiographical memories. This study incorporates mouse-tracking (MT) into aIAT, which offers a more robust technique of memory detection. Participants were assigned to mock crime and then performed the aIAT with MT.

View Article and Find Full Text PDF

To assess whether spinal manipulative therapy (SMT) application procedures (ie, target, thrust, and region) impacted changes in pain and disability for adults with spine pain. Systematic review with network meta-analysis. We searched PubMed and Epistemonikos for systematic reviews indexed up to February 2022 and conducted a systematic search of 5 databases (MEDLINE, EMBASE, CENTRAL [Cochrane Central Register of Controlled Trials], PEDro [Physiotherapy Evidence Database], and Index to Chiropractic Literature) from January 1, 2018, to September 12, 2023.

View Article and Find Full Text PDF

Impact of measurement location on direct mitral regurgitation quantification using 4D flow CMR.

J Cardiovasc Magn Reson

January 2025

Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA. Electronic address:

Background: Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) shows promise for quantifying mitral regurgitation (MR) by allowing for direct regurgitant volume (RVol) measurement using a plane precisely placed at the MR jet. However, the ideal location of a measurement plane remains unclear. This study aims to systematically examine how varying measurement locations affect RVol quantification and determine the optimal location using the momentum conservation principle of a free jet.

View Article and Find Full Text PDF

Purpose: To improve the current method for MRI turbulence quantification which is the intravoxel phase dispersion (IVPD) method. Turbulence is commonly characterized by the Reynolds stress tensor (RST) which describes the velocity covariance matrix. A major source for systematic errors in MRI is the sequence's sensitivity to the variance of the derivatives of velocity, such as the acceleration variance, which can lead to a substantial measurement bias.

View Article and Find Full Text PDF

Unlabelled: In recent years, the EnodePro device has been one of the most frequently used velocity sensors to track the bar velocity in resistance training, with the aim of providing load-velocity profiles. However, recent articles highlight a lack of reliability and validity in the estimated maximal strength, which can cause a serious health risk due to the overestimation of the bar velocity. With this study, we aimed to investigate whether imprecision in the measurement could explain the variance in this measurement error.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!