Modular, porous-coated, titanium segmental endoprostheses were implanted bilaterally in the femoral diaphysis of 7 adult mixed-breed dogs. Autogenous bone graft in particle form was placed around the implant and bone. In 1 limb, homologous fibrin adhesive was mixed with the graft in situ before soft tissue closure. The contralateral limb was grafted in identical manner, but without fibrin adhesive, and served as a control. Radiography was performed immediately after surgery and 1, 2, 3, 4, 6, 8, 10, and 12 weeks later to assess callus area and bone remodeling. At 12 weeks, dogs were euthanatized and bone/implant fixation strength was tested under torsion and compared with values for 6 in vitro controls. Histomorphometric and microradiographic analyses of transverse sections of the distal portion of the implanted femurs were performed. Radiographic callus area was significantly (P < 0.05) smaller in the femurs grafted with fibrin adhesive, compared with the contralateral control. New bone formation (21.4 +/- 1.8% vs 19.2 +/- 2.4%), unlabeled bone (64.8 +/- 3.0% vs 67.9 +/- 4.2%), porosity (13.9 +/- 0.7% vs 12.9 +/- 0.8%), and bone ingrowth into the porous coating (10.3 +/- 0.9% vs 10.0 +/- 1.2%) were not significantly different between fibrin- and nonfibrin-grafted implants, respectively. There were no significant differences in torsional strength of implant fixation between the fibrin- and nonfibrin-grafted femurs or between the in vivo implanted femurs and the in vitro controls.(ABSTRACT TRUNCATED AT 250 WORDS)
Download full-text PDF |
Source |
---|
ACS Appl Bio Mater
January 2025
Department of Materials Engineering, Isfahan University of Technology, Isfahan 84156-83111, Iran.
Burns carry a large surface area, varying in shapes and depths, and an elevated risk of infection. Regardless of the underlying etiology, burns pose significant medical challenges and a high mortality rate. Given the limitations of current therapies, tissue-engineering-based treatments for burns are inevitable.
View Article and Find Full Text PDFCells
December 2024
Department of Biochemistry, College of Medicine, Ewha Womans University, Seoul 07804, Republic of Korea.
In general, the nerve cells of the peripheral nervous system regenerate normally within a certain period after the physical damage of their axon. However, when peripheral nerves are transected by trauma or tissue extraction for cancer treatment, spontaneous nerve regeneration cannot occur. Therefore, it is necessary to perform microsurgery to connect the transected nerve directly or insert a nerve conduit to connect it.
View Article and Find Full Text PDFJ Indian Soc Periodontol
December 2024
Department of Periodontology, K. M. Shah Dental College and Hospital, Sumandeep Vidyapeeth, Vadodara, Gujarat, India.
CRSLS
January 2025
Northwell Health-Lenox Hill Hospital, New York, NY. (Drs. Chu, Alden, and Seckin).
Introduction: There is a risk of iatrogenic vascular injuries during robotic-assisted laparoscopic excision of diaphragmatic endometriosis. Although studies are limited, the first reported case of a suprahepatic inferior vena cava (IVC) injury during robotic diaphragmatic endometriosis excision was successfully treated using a fibrin sealant patch, preventing exsanguination and conversion to laparotomy.
Case Description: A 36-year-old female with a history of recurrent catamenial pneumothorax and two prior video-assisted thoracoscopic surgeries to treat diaphragmatic endometriosis presented to our clinic with right-sided shoulder pain and a chest tube in place.
Med Sci (Basel)
December 2024
Laboratory of Experimental Surgery and Surgical Research "N.S. Christeas", School of Medicine, National and Kapodistrian University of Athens, 11527 Athens, Greece.
Burn injuries remain a major clinical problem worldwide, which require special management by experienced plastic surgeons. However, they cannot be available in every healthcare unit; consequently, there is a need for effective treatment options that could be utilized by a wide range of non-expert healthcare professionals. The aim of the present experimental study was to investigate the safety and efficacy of using a fibrin sealant (TISSEEL) compared to the conventional treatment with sulfadiazine on partial-thickness burn in a rat animal model.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!