A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Buildup region of high-energy x-ray beams in radiosurgery. | LitMetric

Buildup region of high-energy x-ray beams in radiosurgery.

Med Phys

Department of Physics, McGill University, Montréal, Québec, Canada.

Published: September 1993

The depths of dose maxima of radiosurgical x-ray beams increase with the field diameter in the range from 10-30 mm. Furthermore, the degree of the increase is proportional to the photon beam energy. This behavior is in contrast to that of large radiotherapeutic fields, where the depths of dose maxima decrease with increasing field size. The surface doses, depths of dose maxima, and collimator scatter factors for radiosurgical beams with energies between 6 and 18 MV are presented. It is shown that the change in dmax for radiosurgical beams is a result of photon scatter in the phantom rather than in the collimator. Monte Carlo simulations of the radiosurgical beams are used to separate the total dose into two components: the primary dose and the scattered dose. Calculations indicate that buildup region characteristics are governed by the primary dose deposition in the medium. The scattered dose has a minimal effect on the total dose deposited in media by radiosurgical beams.

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.597030DOI Listing

Publication Analysis

Top Keywords

radiosurgical beams
16
depths dose
12
dose maxima
12
dose
9
buildup region
8
x-ray beams
8
total dose
8
primary dose
8
scattered dose
8
beams
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!