The range of wavelengths used in ophthalmic photocoagulation treatment has been greatly enlarged by the development of the dye laser. To investigate the efficacy and possible side effects of orange dye laser light in the treatment of diabetic retinopathy, we performed a prospective, controlled clinical study comparing argon blue-green and orange dye laser light. In 14 patients with diabetic retinopathy of equal severity in both eyes one eye was randomly assigned to either blue-green argon (488 and 514.5 nm) or orange dye (600 nm) panretinal laser treatment. The total coagulated area was the same in both eyes. Subjective parameters (visual acuity, perimetry, color vision) as well as objective functions (electroretinography, electro-oculography) and the clinical course were studied preoperatively and then postoperatively over a period of 6 months. Dye laser coagulation proved as effective and safe as blue-green argon laser coagulation in the panretinal treatment of diabetic retinopathy. No significant differences in postoperative retinal function were detected. However, orange laser coagulation proved significantly more painful than blue-green argon laser treatment (P = 0.002).

Download full-text PDF

Source
http://dx.doi.org/10.1007/BF00919027DOI Listing

Publication Analysis

Top Keywords

dye laser
20
diabetic retinopathy
16
laser coagulation
16
orange dye
12
blue-green argon
12
laser
9
laser light
8
treatment diabetic
8
laser treatment
8
coagulation proved
8

Similar Publications

Albumin-Energized NIR-II Cyanine Dye for Fluorescence/Photoacoustic/Photothermal Multi-Modality Imaging-Guided Tumor Homologous Targeting Photothermal Therapy.

J Med Chem

January 2025

Marshall Laboratory of Biomedical Engineering, International Cancer Center, Laboratory of Evolutionary Theranostics (LET), School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen 518055, China.

Endowing cyanine dyes with hydrophilicity, long blood circulation, tumor targeting, and robust therapeutic efficacy in the second near-infrared (NIR-II) window is challenging for cancer treatment. Herein, we develop cancer cell membrane-coated albumin-NIR-II cyanine dye assemblies, denoted as LZ-1105@HAm, to optimize the photophysical properties of cyanine dyes in aqueous solution for NIR-II fluorescence (FL)/photoacoustic (PA)/photothermal (PT) multimodality imaging-guided tumor homologous targeting photothermal therapy. LZ-1105@HAm exhibits good hydrophilicity, extends the half-life of blood circulation from 0.

View Article and Find Full Text PDF

The photophysical properties of five dyes, i.e., perylene, anthracene, aminoanthracene, 1,6-diphenylhexatriene, and 7-diethylamino-4-methylcoumarin, in solvent and attached to the poly(methyl methacrylate) (PMMA) polymer, were studied via DFT and TD-DFT calculations.

View Article and Find Full Text PDF

High-refractive-index (HRI) dielectrics are gaining increasing attention as building blocks for compact lasers. Their ability to simultaneously support both electric and magnetic modes provides greater versatility as compared to plasmonic platforms. Moreover, their reduced absorption loss minimizes heat generation, further enhancing their performance.

View Article and Find Full Text PDF

This study presents a novel optoporation technique using a titanium-coated TiO microstructure (TMS) device activated by an infrared diode laser for highly efficient intracellular delivery. The TMS device, fabricated with 120 nm titanium coating on a titanium dioxide (TiO) microstructure containing microneedles (height ∼2 μm and width ∼4.5 μm), demonstrates enhanced biocompatibility and thermal conductivity compared to the conventional TiO microstructure (MS).

View Article and Find Full Text PDF

Fañanas cells (FCs) are cerebellar glia of unknown function. First described more than a century ago, they have been almost absent from the scientific literature ever since. Here, we combined whole-cell, patch clamp recordings, near-UV laser photolysis, dye-loading and confocal imaging for a first characterization of FCs in terms of their morphology, electrophysiology and glutamate-evoked currents.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?