A standardbred mare was dosed with 40 mg yohimbine intravenously. Serum and urine samples were collected and analyzed for yohimbine using solvent extraction and reversed-phase high-performance liquid chromatography (HPLC) with fluorescence detection. Maximum yohimbine concentrations of 45 and 18 ng/mL were observed in serum and urine samples, respectively. Elimination was rapid, with half-lives of approximately 20 and 53 min observed for serum and urine, respectively. The presence of yohimbine in these samples was confirmed by liquid chromatography/mass spectroscopy (LC/MS/MS).