A reversed-phase high-performance liquid chromatographic method is described for the measurement of plasma serotonin concentrations. Sample preparation is by a simple solid-phase extraction using C18 columns. An isocratic separation is used with electrochemical detection. The application of the method to the measurement of plasma serotonin concentrations following the administration of fluvoxamine (a serotonin re-uptake inhibitor), maprotiline (a noradrenaline re-uptake inhibitor) and placebo to normal subjects for a seven-day period is reported. Fluvoxamine significantly decreases plasma serotonin over this time period in a linear fashion. No effect on plasma serotonin was seen for maprotiline or placebo. Plasma serotonin concentrations can be used to monitor compliance with fluvoxamine therapy.