Osteolysis and component loosening secondary to polyethylene (PE) debris are of paramount concern to today's joint replacement surgeon. This retrospective clinical study measures linear wear in 568 implanted total hip prostheses in which three different metals were used as bearing surfaces (307 stainless steel T-28 [Zimmer, Warsaw, IN], 162 cobalt chrome Tr-28 [Zimmer], and 99 nonion implanted titanium Miami Orthopedic Surgical Consultants [Biomet, Warsaw, IN] prostheses) implanted by a single surgeon over an 8-year period. The acetabular component in all cases was nonmetal-backed compression-molded PE, and all components were cemented. Linear wear was measured using the radiographic technique described by Livermore et al. (The effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg 72A:518, 1990) in which change in acetabular component thickness is determined from serial radiographs. A separate evaluation of this technique confirmed accuracy to within 0.18 mm. Radiographs were also evaluated for femoral and acetabular radiolucencies, femoral subsidence, and osteolysis. Patients were matched for sex, age, weight, and length of follow-up period to eliminate these retrospective variables for comparison of wear. The patient-matched groups consisted of 77 patients from each group (43 women, 34 men) with the following demographics: age, 66 years; weight, 158.9 lbs.; follow-up period, 7.9 years. Results revealed linear wear rates of 0.06 stainless steel, 0.05 cobalt chrome, and 0.08 titanium in the patient-matched groups.(ABSTRACT TRUNCATED AT 250 WORDS)

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0883-5403(06)80095-1DOI Listing

Publication Analysis

Top Keywords

stainless steel
12
cobalt chrome
12
linear wear
12
acetabular component
12
total hip
8
patient-matched groups
8
warsaw in]
8
follow-up period
8
wear
5
polyethylene wear
4

Similar Publications

The aging population necessitates a critical need for medical devices, where polymers-based surface lubrication coating is essential for optimal functionality. In fact, lubrication and mechanical requirements vary depending on the service environment of different medical devices. Until now, key mean is still blank for general preparation of hydrophilic polymers-based lubrication coatings with on-demand mechanics and lubricity.

View Article and Find Full Text PDF

The aim of the study was to investigate the influence of the nitrocarburizing process carried out in low temperature plasma using the active screen at 440 °C on the structure and physicochemical properties of the 316LVM steel. In the paper, results of micro-structure and phase composition of the layers, roughness, and surface wettability, potentiodynamic pitting corrosion resistance, penetration of ions into the solution as well as biological tests were present. The studies were conducted for the samples of both mechanically polished and nitrocarburized surfaces, after sterilization, and exposure to the Ringer's solution.

View Article and Find Full Text PDF

In this contribution, we apply our newly developed ball-milling platform, which combines Raman spectroscopy and thermal (IR) imaging, as well as acoustic and high-speed optical video recordings, to the synthesis and transformation of citric acid-isonicotinamide (1:2) cocrystal polymorphs in transparent PMMA jars. Particularly, we demonstrate how Raman, temperature, acoustic, and video data are complementary and enable detection and connection of chemical and physical events happening during ball-milling in a time-resolved manner. Importantly, we show that the formation of the three cocrystal polymorphs can be detected through acoustic analyses solely.

View Article and Find Full Text PDF

Accelerated Destruction of Passive Film and Microbial Corrosion of 316L Stainless Steel via Extracellular Electron Transfer.

Angew Chem Int Ed Engl

January 2025

Northeastern University, Corrosion and Protection Center, NO. 3-11, Wenhua Road, Heping District, Shenyang, P. R. China, Shenyang, CHINA.

The dense passive film on 316L stainless steel is the key in its corrosion resistance. Its interactions with an electroactive biofilm are critical in deciphering microbial corrosion. Herein, an in-depth investigation using genetic manipulations and addition of an exogenous electron mediator found that extracellular electron transfer (EET) mediated by the electroactive S.

View Article and Find Full Text PDF

This study explores and discusses the design, the manufacturing and the morphology of three-dimensional (3D) multilayered weft interlaced woven fabrics using stainless steel fibers on the electromagnetic shielding efficiency (SE). Design solutions of 3D multilayered interlaced fabrics in relation to electromagnetic shielding efficiency are still not sufficiently investigated. Moreover, this study aims to analyze the differences in the internal geometry of 3D multilayered weft interlaced fabrics with different number of layers and frequency of connecting points in multilayered woven fabrics on electromagnetic SE.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!