In patients with chronic renal failure (CRF) (CCr less than 20 ml/min), we have previously demonstrated greater rates of Na excretion (ex) when Na intake was nearly all NaHCO3 as compared to NaCl (both 200 mEq Na daily). Chloride (Cl) wasting on NaHCO3 (with severe Cl restriction) occurred, however, and may in part explain the results. To avoid Cl restriction in 6 patients with CRF (CCr 10-15 ml/min) on an estimated 10 mEq Na and Cl diet, electrolyte ex was compared on NaCl supplements of 200 mEq/day versus a daily mixture of NaHCO3 (100mEq) and NaCl (100 mEq). Periods on NaCl and the mixture lasted 4 days (order randomized) separated by re-equilibration to baseline weight (wt). Mean +/- SEM ex of Na, Cl, HCO3 mEq/day and CCr and deltawt (lbs) are compared below for the 4th day of NaCl vs NaHCO3 intake. (see article). Also there were no significant differences in K excretion, blood pressure, or plasma renin activities. Mean serum HCO3 increased from 21.2 to 25.8 mEq/l (day 1 vs 5, P less than 0.01) reflecting the net positive HCO3 balance on the mixture indicated above. Thus increments of Na intake above a fixed NaCl intake were excreted similarly whether given as NaCl or NaHCO3. Greater Na ex on NaHCO3 may depend on severe Cl restriction and/or higher serum HCO3 levels. If dietary NaCl intakes are near maximum tolerance, NaHCO3 supplementation should be accompanied by reductions in NaCl intake to maintain Na balance,
Download full-text PDF |
Source |
---|
Pest Manag Sci
January 2025
Department of Crop Protection, Zhejiang Agriculture and Forest University, Hangzhou, China.
Background: Tobacco brown spot (TBS) caused by Alternaria alternata is one of the most common diseases of tobacco in China, resulting in large loss in yield and quality. Demethylation inhibitors (DMIs) such as tebuconazole are commonly used pesticides to control TBS. However, their control effect has shown a downward trend in recent years.
View Article and Find Full Text PDFWorld J Microbiol Biotechnol
January 2025
Key Laboratory of Smart Breeding (Co-construction by Ministry and Province), Ministry of Agriculture and Rural Affairs, Tianjin Agricultural University, Tianjin, 300392, P.R. China.
Revealing the differences of metabolite profiles of H. pluvialis during hyperaccumulation of astaxanthin under the high salinity and nitrogen deficiency conditions was the key issues of the present study. To investigate the optimum NaCl and NaNO concentration and the corresponding metabolic characteristic related to the astaxanthin accumulation in H.
View Article and Find Full Text PDFAppl Radiat Isot
December 2024
Radiopharmacy Unit, Department of Pharmacy, Groupement Hospitalier Sud - Hospices Civils de Lyon, 165 chemin du Grand Revoyet, 69495, Pierre-Bénite, France; Department of Pharmacy - Groupement Hospitalier Sud - Hospices Civils de Lyon, 165 chemin du Grand Revoyet, 69495, Pierre-Bénite, France.
For hepatobiliary scintigraphy, the radiopharmaceutical drug, ETIFENIN (TECHIDA®), labelled with technetium-99m, is used as a substitute for MEBROFENIN (CHOLEDIAM®). It is generally accepted that radiopharmaceuticals should be checked prior to injection, in particular by determining radiochemical purity, to ensure high-quality images. Radiochromatographic techniques or methods described in the Summary of Product Characteristics (SmPC) and the European Pharmacopeia (Ph.
View Article and Find Full Text PDFEnviron Sci Technol
January 2025
U.S. Environmental Protection Agency, E205-02, Research Triangle Park, P.O. Box 12055, Durham, North Carolina 27711, United States.
The complex, varied composition (i.e., rubbers/elastomers, carbon black, fillers, additives, and embedded road materials) and wide density range of tire road wear particles (TRWPs) present challenges for their isolation and identification from environmental matrices.
View Article and Find Full Text PDFEnviron Sci Process Impacts
January 2025
Massachusetts Institute of Technology, Department of Civil and Environmental Engineering, Parsons Laboratory, 15 Vassar Street, Cambridge, Massachusetts 02139, USA.
The high salinity and organic content in oil and gas wastewaters can cause ion suppression during liquid chromatography mass spectrometry (LC/MS) analysis, diminishing the sensitivity and accuracy of measurements in available methods. This suppression is severe for low molecular weight organic compounds such as ethanolamines (, monoethanolamine (MEA), diethanolamine (DEA), triethanolamine (TEA), -methyldiethanolamine (MDEA), and ,-ethyldiethanolamine (EDEA)). Here, we deployed solid phase extraction (SPE), mixed-mode LC, triple quadrupole MS with positive electrospray ionization (ESI), and a suite of stable isotope standards (, one per target compound) to correct for ion suppression by salts and organic matter, SPE losses, and instrument variability.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!