Ten humeri and ten femora were radiographed in nine positions of longitudinal rotation. In each position total, medullary and cortical widths of the diaphyses (TW, MW, CW) were measured to assess the effect of rotation on these dimensions. The results were expressed as differences from the values in the neutral position (delta TW, delta MW, delta CW). In the humerus, medial rotation produced greater changes than lateral rotation. Though rotation in either direction increased CW, the systematic error due to medial rotation to only 5 degrees (approximately +0.0058 cm per degree) was more than double that due to lateral rotation. In the femur, lateral rotation had the greater effect, producing a marked decrease in CW (approximately -0.0072 cm per degree). Medial rotation produced only a slight increase in CW. The ratios CW/TW ("cortical index") and CA/TA ("area ratio") were calculated and expressed as differences from the values in the neutral position (delta CW/TW, delta CA/TA). Rotation affected these variables much less than the linear dimensions. Furthermore, through the variance of delta TW, delta MW and delta CA/TA increased only slightly or not at all. These results suggest that if radiographic morphometry is to be applied to the humerus and femur, these ratios rather than transverse dimensions should be used. Sequential changes in CW may be totally obscured by small rotational errors.

Download full-text PDF

Source
http://dx.doi.org/10.1259/0007-1285-50-589-23DOI Listing

Publication Analysis

Top Keywords

delta delta
16
medial rotation
12
lateral rotation
12
rotation
11
humerus femur
8
expressed differences
8
differences values
8
values neutral
8
neutral position
8
delta
8

Similar Publications

Feasibility of on-site CT-FFR analysis on cardiac photon-counting CT in evaluation of hemodynamically significant stenosis in comparison to invasive catheter angiography.

Eur J Radiol

January 2025

Department of Radiology and Nuclear Medicine, University Medical Center Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany. Electronic address:

Objectives: Coronary CT angiography (CCTA) is an excellent tool in ruling out coronary artery disease (CAD) but tends to overestimate especially highly calcified plaques. To reduce diagnostic invasive catheter angiographies (ICA), current guidelines recommend CT-FFR to determine the hemodynamic significance of coronary artery stenosis. Photon-Counting Detector CT (PCCT) revolutionized CCTA and may improve CT-FFR analysis in guiding patients.

View Article and Find Full Text PDF

The cortical tracking of the acoustic envelope is a phenomenon where the brain's electrical activity, as recorded by electroencephalography (EEG) signals, fluctuates in accordance with changes in stimulus intensity (the acoustic envelope of the stimulus). Understanding speech in a noisy background is a key challenge for people with hearing impairments. Speech stimuli are therefore more ecologically valid than clicks, tone pips, or speech tokens (e.

View Article and Find Full Text PDF

Passive earth pressure analysis considering hydraulic and mechanical hysteresis for unsaturated soil.

PLoS One

January 2025

Water Resources Engineering Department, College of Engineering, Salahaddin University, Erbil, Iraq.

This paper addresses the mechanical characteristics of a passive earth pressure problem taking into account water retention curve (SWRC) hysteresis. Both hydraulic (drying and wetting cycles) and mechanical hysteresis were considered. Parametric studies were carried out at various air entry values (AEV = 5-30 kPa), different wall frictions (δ = 0, 0.

View Article and Find Full Text PDF

Mesenchymal stem cell (MSC)-based bone tissue regeneration has gained significant attention due to the excellent differentiation capacity and immunomodulatory activity of MSCs. Enhancing osteogenesis regulation is crucial for improving the therapeutic efficacy of MSC-based regeneration. By utilizing the regenerative capacity of bone ECM and the functionality of nanoparticles, we recently engineered bone-based nanoparticles (BNPs) from decellularized porcine bones.

View Article and Find Full Text PDF

Whitening: is Omnichroma universal composite unchanging? Spectrophotometric evaluation.

J Clin Exp Dent

December 2024

Department of Surgical Sciences, Pediatrics and Gynecology, University of Verona, P.le L.A.Scuro, 10, 37134 Verona, Italy.

Background: This study aimed to evaluate the color stability of Class V anterior restorations with universal composite after professional bleaching using a spectrophotometer.

Material And Methods: Class V cavities were prepared and restored with universal composite in twenty-eight extracted anterior teeth. One week after restoration, color analysis was performed using the spectrophotometer.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!