A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Specific flow injection sandwich binding assay for IgG using protein A and a fusion protein. | LitMetric

A sandwich-type flow-injection binding assay for quantitation of various IgG's was developed. The assay is based on the pseudoimmunological reaction between protein A from Staphylococcus aureus and immunoglobulin G from different species. Protein A immobilized on a solid support and a fusion protein of protein A and beta-galactosidase from Escherichia coli are used for detection. The fusion protein is produced with a temperature-inducible recombinant E. coli strain. A sandwich is formed by subsequent injection of IgG and fusion protein into the buffer stream flowing through the immobilized protein A column. The amount of enzyme activity bound is proportional to the amount of IgG bound and is measured by pumping a lactose solution as substrate for beta-galactosidase through the protein A column. Lactose is converted to glucose and galactose. The detector is an enzyme thermistor that measures the heat evolved in the enzymatic conversion of glucose by coimmobilized glucose oxidase and catalase. The assay takes 16 min at a flow rate of 0.6 mL min-1 with a lower detection limit of 33 pmol per injection of rabbit IgG. The precision of replicate measurements has a standard deviation of 4-5%, and the column can be used for more than 50 cycles.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ac00071a006DOI Listing

Publication Analysis

Top Keywords

fusion protein
16
protein
10
binding assay
8
protein column
8
specific flow
4
flow injection
4
injection sandwich
4
sandwich binding
4
assay
4
igg
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!