Penetrating keratoplasty was performed in 39 consecutive patients. A 16 bite 10-0 nylon continuous suture was used. Post-operatively, the suture was adjusted to reduce astigmatism, as determined by refraction, keratoscopy and keratometry. Suture adjustment was performed if astigmatism was over 4 dioptres (D). The suture was tightened in the flatter meridian and loosened in the steeper meridian. Twenty-one patients had suture adjustment performed. Prior to adjustment, mean (+/- standard deviation) astigmatism measured 6.33 +/- 1.38 D. Following adjustment, mean astigmatism was significantly reduced to 2.69 +/- 1.14 D (p < 0.0001). The average final astigmatism for the entire group was 2.66 +/- 1.12 D. The use of a continuous adjustable suture in penetrating keratoplasty significantly reduced the post-operative astigmatism in a group of patients undergoing penetrating keratoplasty.