A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Benzodiazepine receptor equilibrium constants for flumazenil and midazolam determined in humans with the single photon emission computer tomography tracer [123I]iomazenil. | LitMetric

This study is based on the steady state method for the calculation of Kd values recently described by Lassen (J. Cereb. Blood Flow Metab. 12 (1992), 709), in which a constant infusion of the examined nonradioactive ligand is used with a bolus injection of tracer. Eight volunteers were examined twice, once without receptor blockade and once with a constant degree of partial blockade of the benzodiazepine receptors by infusion of nonradioactive flumazenil (Lanexat) or midazolam (Dormicum). Single photon emission computer tomography and blood sampling were performed intermittently for 6 h after bolus injection of [123I]iomazenil. The tracer in plasma was determined by high-pressure liquid chromatography and also by a simple octanol extraction procedure. The free concentration of flumazenil and midazolam in plasma water averaged 52% and 3.5% of that in whole plasma. The Kd values for the entire cortical rim for flumazenil were 7.4, 10.0, 10.3 and 17.7 nmol/l plasma water and, for midazolam, 73, 76, 58 and 30 nmol/l plasma water. The variation exceeds random methodological error and is probably due to interindividual differences in receptor affinity. The Kd level of midazolam is considerably higher than expected from the results of in vitro studies.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0014-2999(93)90660-aDOI Listing

Publication Analysis

Top Keywords

plasma water
12
flumazenil midazolam
8
single photon
8
photon emission
8
emission computer
8
computer tomography
8
bolus injection
8
nmol/l plasma
8
midazolam
5
plasma
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!