This study compares the relative thermal damage caused by a surgical CO2 laser and the Erbium:YAG laser when used to incise the human vocal fold in vitro. Results show that charring is completely eliminated when using the Erbium:YAG laser. The depth of coagulative necrosis adjacent to an incision is reduced from 510 microns (+/- 75) using the CO2 laser to 23 microns (+/- 12) using the Ebrium:YAG laser and at the base is reduced from 125 microns (+/- 45) using the CO2 laser to 12 microns (+/- 8) using the Erbium:YAG laser. The potential advantages regarding post-operative healing after laryngeal surgery are discussed.

Download full-text PDF

Source
http://dx.doi.org/10.1017/s0022215100124764DOI Listing

Publication Analysis

Top Keywords

microns +/-
16
co2 laser
12
erbiumyag laser
12
laser
9
laryngeal surgery
8
+/- co2
8
laser microns
8
vitro comparison
4
comparison erbium
4
erbium yag
4

Similar Publications

Purpose: In locations where the proton energy spectrum is broad, lineal energy spectrum-based proton biological effects models may be more accurate than dose-averaged linear energy transfer (LET) based models. However, the development of microdosimetric spectrum-based biological effects models is hampered by the extreme computational difficulty of calculating microdosimetric spectra. Given a precomputed library of lineal energy spectra for monoenergetic protons, a weighted summation can be performed which yields the lineal energy spectrum of an arbitrary polyenergetic beam.

View Article and Find Full Text PDF

Grids designed for tomography: Stereovision transmission electron microscopy makes it easy to determine the winding handedness of helical nanocoils.

Micron

January 2025

Health and Medical Research Institute, Department of Life Science and Biotechnology, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba Central-6, 1-1-1 Higashi, Tsukuba, Ibaraki 305-8566, Japan. Electronic address:

Determining the handedness of helical nanocoils using transmission electron microscopy (TEM) has traditionally been challenging due to the deep depth of field and transmission nature of TEM, complementary techniques are considered necessary and have been practiced such as low angle rotary shadowing, scanning electron microscopy (SEM), or atomic force microscopy (AFM). These methods require customized sample preparation, making direct comparison difficult. Inspired by the need to identify the helical winding direction from TEM images alone, we developed a specialized tomography grid to capture stereo-pair images, enabling stereopsis.

View Article and Find Full Text PDF

Despite being a high-resolution separation technique, deterministic lateral displacement (DLD) technology is facing multiple challenges with regard to design, manufacture, and operation of pertinent devices. This work specifically aims at alleviating difficulties associated with design and manufacture of DLD chips. The process of design and production of computer-aided design (CAD) mask layout files that are typically required for computational modeling analysis, optimization, as well as for manufacturing DLD-based micro/nanofluidic chips is complex, time-consuming, and often necessitates a high level of expertise in the field.

View Article and Find Full Text PDF

4.5-Year Follow-up with a Novel Corneal Endothelial Prosthesis.

Klin Monbl Augenheilkd

January 2025

Ophthalmology, Amsterdam UMC, Amsterdam, Netherlands.

Background: Refractory corneal edema is the foremost reason for endothelial corneal transplantation (EK) in the world. Descemet membrane endothelial keratoplasty (DMEK) and Descemet stripping automated endothelial keratoplasty (DSAEK) offer good clinical outcomes. However, human donor tissue is limited in availability and has a complex logistical chain.

View Article and Find Full Text PDF

Inefficient endosomal escape has been regarded as the main bottleneck for intracellular nucleic acid delivery. While most research efforts have been spent on designing various nano-sized particles, we took a different path here, investigating micron-sized carriers for direct cytosol entry. Using the spontaneous co-assembly of mRNA and the designer 27 amino acid oligopeptide named pepMAX2, micron-sized co-assemblies were obtained with various sizes by altering the concentration of NaCl salt and time for pre-incubation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!