In the past few years, echocardiography has emerged as a useful noninvasive clinical tool in cardiac diagnosis. Conventional methods for analyzing echocardiographic data involve time consuming and tedious manual techniques for measuring various distances and computing cardiac parameters of interest. This paper describes a useful method for automating the analysis of M scan echocardiograms both for routine clinical work as well as for special research oriented ultrasonic cardiac studies. Using a GRAF/PEN digitizer interfaced to a PDP-11 minicomputer system, relevant points of the ventricular and mitral valve interfaces, R-R intervals, and time and distance calibration points are entered from hard copies of M scan echocardiograms. The computer then determines all the parameters of interest such as left ventricular (LV) diameters, LV volumes, LV mass, ejection fraction, stroke volume, cardiac output, septal and posterior wall dynamics, as well as such mitral valve (MV) parameters as opening/closing velocities, excursions, and areas subtended by both MV leaflets. The data and results are stored on disc or tape and a report of the results is immediately available from a printer for incorporation into the patient's record file.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jcu.1870040305DOI Listing

Publication Analysis

Top Keywords

parameters interest
8
scan echocardiograms
8
mitral valve
8
digital computer
4
computer analysis
4
analysis m-scan
4
m-scan echocardiograms
4
echocardiograms years
4
years echocardiography
4
echocardiography emerged
4

Similar Publications

Luminescent Lanthanide (III) (Ln(III)) bioprobes (LLBs) have been extensively used in the last two decades as intracellular molecular probes in bio-imaging for the efficient revelation of analytes, to signal intracellular events (enzymes/protein activity, antigen-antibody interaction), target specific organelles, and determine parameters of particular biophysical interest, to gain important insights on pathologies or diseases. The choice of using a luminescent Ln(III) coordination compound with respect to a common organic fluorophore is intimately connected to how their photophysical sensitization (antenna effect) can be finely tuned and especially triggered to respond (even quantitatively) to a certain biophysical event, condition or analyte. While there are other reviews focused on how to design chromophoric ligands for an efficient sensitization of Ln(III) ions, both in the visible and NIR region, this review is application-driven: it is a small collection of particularly interesting examples where the LLB's emissive information is acquired by imaging the emission intensity and/or the fluorescence lifetime (fluorescence lifetime imaging microscopy, FLIM).

View Article and Find Full Text PDF

Background The escalating global obesity epidemic requires comprehensive investigations for effective weight management strategies. Understanding the patterns, barriers, and facilitators of dietary interventions is crucial for developing effective weight management protocols. This research aims to assess dietary modification interventions among weight loss subjects in Tamilnadu, South India.

View Article and Find Full Text PDF

Aim: This study aimed to evaluate the impact of using melatonin and vitamin C as adjuncts to the non-surgical treatment of chronic periodontitis.

Materials And Methods: This triple-blind randomized clinical trial involved 100 participants with chronic periodontitis. Subjects were randomly assigned to three groups: (1) non-surgical periodontal therapy (NSPT) alone (n = 33); (2) NSPT with melatonin (n = 33); and (3) NSPT with melatonin and vitamin C (n = 34).

View Article and Find Full Text PDF

Pericardial effusion refers to the accumulation of fluid within the pericardial sac, the double-layered membrane surrounding the heart. It can be caused by various medical conditions and may lead to serious complications if not diagnosed and managed promptly. Point-of-care ultrasound (POCUS) has emerged as a valuable tool in the clinical evaluation of pericardial effusions, offering real-time visualization and aiding in the assessment of its size, characteristics, and potential hemodynamic impact.

View Article and Find Full Text PDF

With the rapid advancement of plant phenotyping research, understanding plant genetic information and growth trends has become crucial. Measuring seedling length is a key criterion for assessing seed viability, but traditional ruler-based methods are time-consuming and labor-intensive. To address these limitations, we propose an efficient deep learning approach to enhance plant seedling phenotyping analysis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!