A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The effect of insufflation leaks upon ventilation. A quantified comparison of ventilators. | LitMetric

Some ventilator-dependent patients use uncuffed tracheostomy tubes, resulting in fluctuations in the minute volume of ventilation. Bedside measurement of ventilation is difficult because of the insufflation and exsufflation leaks. This laboratory study of five different ventilators measured the tidal volumes achieved with three insufflation leaks introduced in an increasing order of magnitude and at three levels of compliance. The largest leak reduced the peak inflation pressure from 26 to 14 cmH2O in two pressure-limited ventilators with a 35% loss of the initial tidal volume of 800 ml. The turbine-driven pressure-limited ventilator retained a peak pressure of 20.5 cmH2O and lost only 14% of the volume, whereas the volume ventilators lost 65% of the tidal volume. The loss of volume was 3% for every cmH2O decrease in airway pressure due to a leak, regardless of the ventilator or compliance. Using the Friedman test, the differences between the volume ventilators and the pressure ventilators were significant whilst the three pressure-limited ventilators did not perform significantly differently from each other.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1365-2044.1994.tb14184.xDOI Listing

Publication Analysis

Top Keywords

insufflation leaks
8
pressure-limited ventilators
8
tidal volume
8
volume ventilators
8
ventilators
7
volume
7
leaks ventilation
4
ventilation quantified
4
quantified comparison
4
comparison ventilators
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!