Renal parenchymal volume is important for clinical interpretation. The phantom study was carried out to validate the volume calculation. The volume of kidney phantom was determined using reoriented single photon emission computed tomography (RSPECT). The phantom volume range was 20-300 ml. There are two major factors in the determination of volume which are radioactivity concentration and organ/background ratio. Our results showed that the effect of radioactivity concentration on the volume in the kidney phantom is -3.3 to 7.5% whereas the effect of organ/background ration was only 2.2%. Our relative volume deviation, therefore, from the real volume was 1.43%. We concluded that it is feasible to use kidney volume in clinical work.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/00006231-199402000-00007 | DOI Listing |
Introduction: Chronic ischemic heart failure is a major global health issue despite advancements in therapy. Stem cell (SC) therapy has emerged as a potential treatment, but its effectiveness remains uncertain. This study aimed to systematically review and meta-analyze the current evidence on SC therapy's efficacy.
View Article and Find Full Text PDFCurr Neurovasc Res
January 2025
Center for Rehabilitation Medicine, Department of Neurology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, Zhejiang, China.
Objective: The concept of "time is brain" is crucial for the reperfusion therapy of ischemic stroke. However, the Infarct Growth Rate (IGR) varies among individuals, which is regarded as a more powerful factor than the time when determining infarct volume and its association with clinical outcomes. For stroke patients with a similar infarct volume, a longer time from stroke Onset to Imaging (OTI) correlates with a lower IGR, which may indicate a better prognosis.
View Article and Find Full Text PDFJ Exp Biol
January 2025
Laboratory of Function and Evolutionary Morphology, FOCUS, Université de Liège, Liège, Belgique.
The inner ear of teleost fishes is known to serve both auditory and vestibular functions. Many studies have compared otoliths from different species and attempted to understand the observed differences within the light of environmental factors. However, experimental data on how otoliths could adapt are scarce.
View Article and Find Full Text PDFCirc Res
January 2025
Burke Neurological Institute, White Plains, NY (H.J., I.P., K.W.P., J.M., A.M., S.C.).
Background: Remote ischemic conditioning (RIC) has been implicated in cross-organ protection in cerebrovascular disease, including stroke. However, the lack of a consensus protocol and controversy over the clinical therapeutic outcomes of RIC suggest an inadequate mechanistic understanding of RIC. The current study identifies RIC-induced molecular and cellular events in the blood, which enhance long-term functional recovery in experimental cerebral ischemia.
View Article and Find Full Text PDFActa Crystallogr A Found Adv
March 2025
Pennsylvania State University, University Park, PA 16802, USA.
X-ray diffraction is ideal for probing the sub-surface state during complex or rapid thermomechanical loading of crystalline materials. However, challenges arise as the size of diffraction volumes increases due to spatial broadening and because of the inability to deconvolute the effects of different lattice deformation mechanisms. Here, we present a novel approach that uses combinations of physics-based modeling and machine learning to deconvolve thermal and mechanical elastic strains for diffraction data analysis.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!