Before research findings are applied to practice, the quality of the research must be assessed so that flawed research does not lead inadvertently to flawed practice. Two critical indicators of research quality are the validity and reliability of the data collection instruments. This article summarizes the principles of instrument validity and reliability and identifies deviations from these principles in a random sample of 55 research studies published in 1989 in five refereed nursing journals targeted toward practicing clinicians. Using a valid and reliable instrument, the investigators found that even with a policy of giving authors "the benefit of the doubt," 47% of the research studies contained no evidence of validity for any data collection instruments and 36% had no evidence of reliability; 29% had no evidence of either validity or reliability. Content validity, a basic requirement for all research instruments, was addressed in only 27% of the studies. This article provides documentation, justification, and suggestions for nursing educators, journal editors, and researchers to take action to improve the reporting of instrument validity and reliability to help ensure the quality of the research on which nursing practice is based.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s8755-7223(05)80041-9DOI Listing

Publication Analysis

Top Keywords

validity reliability
20
instrument validity
12
reporting instrument
8
nursing journals
8
data collection
8
collection instruments
8
evidence validity
8
validity
7
reliability
6
reliability selected
4

Similar Publications

Measurement of Blood Pressure in Children and Adolescents Outside the Office for the Diagnosis of Hypertension.

Curr Cardiol Rep

January 2025

Section of Pediatric Nephrology, Department of Pediatrics, Yale University School of Medicine, New Haven, USA.

Purpose Of Review: To review the benefits of ambulatory blood pressure monitoring and home blood pressure monitoring in children and to discuss implementation of guideline-recommended ambulatory blood pressure monitoring.

Recent Findings: Compared with office blood pressure, ambulatory blood pressure monitoring and home blood pressure monitoring provide superior accuracy, reproducibility, and stronger associations with target organ damage although future work is needed to determine the utility of home blood pressure monitoring to predict hypertension status on ambulatory blood pressure monitoring. Due to the benefits of out-of-office blood pressure measurement, ambulatory blood pressure monitoring has been recommended to confirm the diagnosis of hypertension in children and adolescents since publication of the 2017 American Academy of Pediatrics clinical practice guidelines on hypertension.

View Article and Find Full Text PDF

This study aimed to develop the 'Fear of Feeding My Child- A Parental Report (FF-PR)', which measures the parental fear of feeding their children, and to determine its reliability and validity. The study consists of the developmental phase and reported the content validity, internal consistency, test-retest reliability, construct, criterion, and discriminant validity. The study included two groups; 'Group I (N = 90)' who had a neurological disorder and their parents, and 'Group II (N = 60)' who were typically developing children without any feeding and swallowing problems and their parents.

View Article and Find Full Text PDF

Factor structure and measurement invariance of the Childhood Executive Functioning Inventory (CHEXI) across parents and teachers in Portuguese children.

Child Neuropsychol

January 2025

Center for Research in Neuropsychology and Cognitive and Behavioural Intervention, Faculty of Psychology and Educational Sciences, University of Coimbra, Coimbra, Portugal.

The Childhood Executive Functioning Inventory (CHEXI) is a rating scale that evaluates everyday behaviors associated with executive functions in children. This study aimed to investigate the factor structure and the measurement invariance across parents and teachers of the CHEXI in a sample of 279 Portuguese typically developing children (6 to 12 years old,  = 160 girls and  = 119 boys). Most studies only analyzed the original two-factor model, and the few that investigated the four-factor model found a nearly identical fit between both factor structures.

View Article and Find Full Text PDF

Moroccan Adaptation of the 'Self-Care Behaviour Assessment Scale' for Arteriovenous Fistula in Haemodialysis.

J Ren Care

March 2025

Faculty of Sciences Semlalia, Laboratory of Pharmacology, Neurobiology, Anthropobiology and Environment, Cadi Ayyad University, Marrakech, Morocco.

Background: Arteriovenous fistula self-care behaviours in patients receiving haemodialysis are essential to maintain patency of vascular access and prevent its life-threatening complications. Assessing arteriovenous fistula self-care behaviours in patients receiving haemodialysis requires a reliable and valid tool.

Objective: The aim of this study was to adapt and translate the Portuguese scale for the assessment of self-care behaviours of arteriovenous fistula in patients receiving haemodialysis into the Moroccan dialect and evaluate its psychometric properties in the Moroccan context.

View Article and Find Full Text PDF

Backgrounds: Physical activity is crucial in health promotion. Exercise in groups can strengthen the benefits of exercise itself. However, the scale measuring the motivation for group exercise is scare.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!