Our newly developed axial flow pump consists of a flow tube, an internal rotating impeller, and a fixed flow stator (we call the stator) behind the impeller. This pump produces a flow of 3 to 8 L/min against 50 to 150 mm Hg pressure difference, respectively, in the range of 10,000 to 16,000 rpm. An axial flow pump that will be used as a ventricular assist device (VAD) has to have low hemolytic and good antithrombogenic characteristics. This paper will show how to decrease the hemolytic properties of this axial flow pump systematically using a test matrix. The test variables evaluated were impeller blade tip geometry, impeller flow tube clearance (radial clearance), impeller stator clearance (axial clearance), impeller blade number, stator blade number, and impeller length. All in vitro hemolysis tests were performed at 5.0 L/min against 100 mm Hg pressure difference using a total of 83 bags of fresh bovine blood. The results were as follows: the impeller blade tip geometry did not significantly effect hemolysis, a 0.005-inch and a 0.009-inch radial clearance were significantly (p < 0.01 or 0.001) less hemolytic than the other clearances, a 0.075-inch axial clearance was significantly (p < 0.05) more hemolytic than the other clearances, two- and six-bladed impellers were significantly (p < 0.01 and 0.02, respectively) less hemolytic than a four-bladed impeller, a five-bladed stator was significantly (p < 0.05 or 0.01) less hemolytic than the other stators, and the impeller length did not make a significant difference. Currently, the best index of hemolysis is 0.031 +/- 0.018 g/100 L, and using parameters from these results, implantable devices are being fabricated.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1525-1594.1994.tb03296.xDOI Listing

Publication Analysis

Top Keywords

axial flow
16
flow pump
12
impeller blade
12
impeller
10
flow
8
ventricular assist
8
assist device
8
flow tube
8
pressure difference
8
blade geometry
8

Similar Publications

Objective: A pathogenetic role of CD8+ T lymphocytes in radiographic axial spondyloarthritis (r-axSpA) and other spondyloarthritis (SpA) is sustained by genome-wide association studies (GWAS) and by the expansion of public T cell clonotypes in the target tissues. This study investigates the migration of CD8+ T cells, along with their phenotype and functions in patients with r-axSpA and psoriatic arthritis (PsA).

Methods: Peripheral blood CD8+ and CD4+ T cells were isolated from r-axSpA (n= 128), PsA (n= 60) and rheumatoid arthritis (RA, n= 74) patients and healthy donors (HD, n= 79).

View Article and Find Full Text PDF

Background: The pathophysiologic mechanisms underlying early-onset myopia remain unclear; in this study, we investigate the pathogenesis by examining the interrelationships between axial length to corneal curvature radius ratio ( ) and choroidal blood flow.

Methods: This cross-sectional study included 202 eyes from myopic children, categorized into 141 eyes with mild myopia, 47 eyes with moderate myopia, and 14 eyes with high myopia. Optical coherence tomography angiography (OCTA) was used to measure choroidal blood flow perfusion within a 6 mm × 6 mm area of the macular region, divided into nine subareas based on ETDRS partitioning: macular fovea, nasal side 1, superior 1, temporal side 1, inferior 1, nasal side 2, superior 2, temporal side 2, and inferior 2.

View Article and Find Full Text PDF

Background: Left ventricular assist device (LVAD) has been widely used as an alternative treatment for heart failure, however, aortic regurgitation is a common complication in patients with LVAD support. And the O-A angle (the angle between LVAD outflow graft and the aorta) is considered as a vital factor associated with the function of aortic valve. To date, the biomechanical effect of the O-A angle on the aortic valve remains largely unknown.

View Article and Find Full Text PDF

4D flow cardiac magnetic resonance in pediatric congenital heart disease: Insights from over four years of clinical practice.

Clin Imaging

January 2025

Institute of Clinical sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; Dept of Pediatric Radiology, The Queen Silvia Children's Hospital, Region Västra Götaland, Sahlgrenska University Hospital, Gothenburg, Sweden.

Background: Congenital heart diseases (CHDs) are common birth defects. This work presents over four years of clinical experience of 4D flow cardiovascular magnetic resonance (CMR), highlighting its value for pediatric CHD.

Methods: Children with various CHD diagnoses (n = 298) were examined on a 1.

View Article and Find Full Text PDF

Electrorheological fluids are suspensions that are characterized by a strong functional dependence of their constitutive behavior on the local electric field. While such fluids are known to be promising in different applications of microfluidics including electrokinetic flows, their capabilities of controlling ion transport and preferential solute segregation in confined fluidic systems remain to be explored. In this work, we bring out the unique role of electrorheological fluids in orchestrating the selective enrichment and depletion of charged species in variable area microfluidic channels.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!