Relative amounts of various histone fractions in Drosophila chromatin were estimated densitometrically on electrophoretic gel separations. Several consistent and highly significant differences were obtained between larval and adult chromatin. The arginine-rich histones showed the most conspicuous changes: higher amounts of H4 in larvae, higher H3 in adults. The level of modification of these histones was clearly higher in larval than in adult chromatin. The modification of the two slower subfractions of H4 involved, in all probability, phosphorylation as well as acetylation. In all types of Drosophila chromatin studied 50% or more of the H2a molecules were phosphorylated--a remarkably high proportion. The species differences observed in relative amounts of histone were consistent in both stages of development. D. melanogaster differed from D. hydei and D. virilis in all histones except H2b, while the latter two species were generally similar. The interspecific variation in histone pattern was generally not correlated to differences in content of heterochromatin. The level of modification of H2 was, however, presumably an exception, as it was significantly lower for both larvae and adults in D. virilis than in the other two species. These differ from D. virilis in containing appreciably lower proportions of heterochromatic chromosome segments.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/BF00292833 | DOI Listing |
ACS Appl Mater Interfaces
January 2025
Department of Chemistry and Biochemistry, University of California Santa Barbara, Santa Barbara, California 93106, United States.
Electrochemical aptamer-based (EAB) sensors are a molecular measurement platform that enables the continuous, real-time measurement of a wide range of drugs and biomarkers in situ in the living body. EAB sensors are fabricated by depositing a thiol-modified, target-binding aptamer on the surface of a gold electrode, followed by backfilling with an alkanethiol to form a self-assembled monolayer. And while the majority of previously described EAB sensors have employed hydroxyl-terminated monolayers, a handful of studies have shown that altering the monolayer headgroup can strongly affect sensor performance.
View Article and Find Full Text PDFJ Agric Food Chem
January 2025
College of Veterinary Medicine, Northeast Agricultural University, Harbin 150030, P.R. China.
Pesticides and plastics have brought convenience to agricultural production and daily life, but they have also led to environmental pollution through residual chemicals. Emamectin benzoate (EMB) is among the most widely used insecticides, which can cause environmental pollution and harm the health of organisms. Additionally, microplastics (MPs), a relatively new type of pollutant, not only are increasing in residual amounts within water bodies and aquatic organisms but also exacerbate pollution by adsorbing other pollutants, leading to a mixed pollution scenario.
View Article and Find Full Text PDFInorg Chem
January 2025
Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio 43210, United States.
Three new hexagonal perovskites with CsMMRhCl (M = Na, Ag; M = Mn, Fe) stoichiometry have been synthesized from solution precipitation reactions. These air-stable compounds crystallize as triply cation-ordered variants of the 6H perovskite structure. This structure contains octahedra that share a common face to form MRhCl dimers that are arranged on a two-dimensional triangular network.
View Article and Find Full Text PDFDigit Health
January 2025
Department of Occupational Science and Occupational Therapy, University of British Columbia, Vancouver, BC, Canada.
Background: TikTok is a global social media platform with over 1 billion active users. Presently, there are few data on how TikTok users navigate the platform for mental health purposes and the content they view.
Objective: This study aims to understand the patterns of mental health-related content on TikTok and assesses the accuracy and quality of the advice and information provided.
Front Med (Lausanne)
January 2025
Department of Gynecology and Obstetrics, International Peace Maternity and Child Health Hospital Shanghai Jiao Tong University School of Medicine, Shanghai Key Laboratory of Embryo Original Diseases, Shanghai Municipal Key Clinical Specialty, Shanghai, China.
Background: An intrauterine device (IUD) is a widely used long-term contraceptive device for family planning. However, the IUD can lead to various complications. Severe complications and remedial measures caused by IUDs have been reported in the literature; however, detailed surgical approaches for safely removing the IUD within the minimum surgical range have rarely been described especially in postmenopausal women.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!