31P MRS examinations of the brain of 10 healthy volunteers were performed to determine T2 of the coupled ATP signals by use of the localized 90 degrees-TE/2-2662-TE/2-acq frequency selective spin echo sequence for elimination of phase and intensity distortions. The T2 relaxation times obtained are much longer than usually assumed: gamma-ATP: 89 +/- 9 ms; alpha-ATP: 84 +/- 6 ms; beta-ATP: 62 +/- 3 ms.

Download full-text PDF