A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Diagnosis of unilateral mainstem bronchial obstruction following single-lung transplantation with routine spirometry. | LitMetric

Single-lung transplantation has become a treatment option for many patients with advanced pulmonary disease. Recent advances in surgical technique and refined immunosuppressive regimens have led to improvement in long-term outcomes, but postoperative complications, including airway disorders, remain problematic. Serial spirometry with flow-volume loops is sensitive in detecting early small-airway disease associated with lung allograft rejection or bronchiolitis obliterans, but its role in the diagnosis of large-airway disease in the posttransplantation setting has not been delineated. In this report, we describe a novel alteration in the configuration of the flow-volume loop in a patient who developed unilateral mainstem bronchial obstruction following single-lung transplantation for severe emphysema. Surveillance spirometry performed 6 weeks after transplantation demonstrated a new initial plateau in the maximal expiratory flow-volume curve suggestive of a variable intrathoracic airway obstruction. This unique aberration in the flow-volume curve sheds new insight into the physiologic abnormalities of spirometry in patients receiving lung transplants.

Download full-text PDF

Source
http://dx.doi.org/10.1378/chest.103.4.1255DOI Listing

Publication Analysis

Top Keywords

single-lung transplantation
12
unilateral mainstem
8
mainstem bronchial
8
bronchial obstruction
8
obstruction single-lung
8
flow-volume curve
8
diagnosis unilateral
4
transplantation
4
transplantation routine
4
spirometry
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!