A Standard Specification for Transferring Digital Neurophysiological Data Between Independent Computer Systems (Designation E 1467-92) has been developed. The specification defines a common representation of all of the data associated with a complete clinical study, including digitized neurophysiological waveforms, textual annotations and interpretive reports. Patterned after existing, related healthcare data interchange standards, it will facilitate data interchange between neurophysiological instruments, computer systems within the neurophysiology laboratory, other information systems in the hospital, and outside healthcare facilities or research laboratories.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2850682 | PMC |
Sensors (Basel)
December 2024
Department of Civil and Environmental Engineering, Villanova University, 800 Lancaster Avenue, Villanova, PA 19085, USA.
The ability to track moisture content using soil moisture sensors in green stormwater infrastructure (GSI) systems allows us to understand the system's water management capacity and recovery. Soil moisture sensors have been used to quantify infiltration and evapotranspiration in GSI practices both preceding, during, and following storm events. Although useful, soil-specific calibration is often needed for soil moisture sensors, as small measurement variations can result in misinterpretation of the water budget and associated GSI performance.
View Article and Find Full Text PDFJ Transl Med
January 2025
Research Group Movement Sciences and Sport (MS&SPORT), Department of Physical Activity and Sport, Faculty of Sport Sciences, University of Murcia, Murcia, Spain.
Background: Accurate body fat distribution assessment is essential for managing cardiovascular disease and metabolic disorders. Although several methods are available for segmental fat analysis, few studies have examined the validity of affordable methods such as Bioelectrical Impedance Analysis (BIA) against the reference method, Dual-Energy X-ray Absorptiometry (DXA). This study aimed to assess the validity of BIA as compared to DXA for segmental fat mass assessment, and to develop anthropometric multivariate regression models that offer a cost-effective alternative for health professionals in clinical and public health settings.
View Article and Find Full Text PDFSci Rep
January 2025
Computer Science Department, Al Al-Bayt University, Mafraq, 25113, Jordan.
Electrochemical energy conversion technologies include proton exchange membrane fuel cells (PEMFCs) where proton interchange is an alternative to diesel distributed generation, and PEMFCs are considered as a promising backup power source and a tool to regulate power consumption. Some of the major benefits of these PEMFCs especially in power system applications include low emission of carbon, fast load following capability, no noise and high start-up reliability. It is challenging to find the best PEMFC parameters because the model is complex and the problem is nonlinear; not all optimization algorithms can solve this problem.
View Article and Find Full Text PDFVet Med Sci
January 2025
Department of Statistics, Faculty of Science, University of Muğla Sıtkı Koçman, Muğla, Turkey.
Background: There is a lack of data on the validation and diagnostic performance of the Freestyle Optium Neo-H (Freestyle) and Centrivet GK (Centrivet) devices for the diagnosis of hypoglycaemia, hyperglycaemia and hyperketonaemia in goats.
Objectives: The aim of the present study was to validate the Freestyle and Centrivet for the analysis of whole blood beta-hydroxybutyric acid (BHBA) and to validate the Freestyle for the analysis of whole blood glucose concentrations using the reference method (RM) in goat blood collected from the jugular and ear veins.
Methods: Venous blood samples were utilised to assess glucose and BHBA concentrations using the Freestyle, Centrivet and RM.
J Contemp Dent Pract
September 2024
Department of Preventive and Restorative Dentistry, School of Dental Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, United States.
Aim: The purpose of this study is to investigate the interchangeability of newly acquired, short-term used, and long-term used semi-adjustable articulators.
Materials And Methods: Metal analogs of partially dentate maxillary and mandibular arches were mounted on twelve semi-adjustable Stratos 300 articulators, divided into three groups based on usage over time: New, short-term used (<2 years), long-term used (>2 years) articulators. Each articulator was calibrated according to manufacturer guidelines, ensuring consistency.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!