This paper considers one way that occupational health professionals can assess the force exerted by keyboard users and the possible relationship between that force and the key force-displacement relationship. First, three personal-computer keyboards with the standard QWERTY layouts were tested as described by the American National Standard for Human Factors Engineering of Visual Display workstations (ANSI/HFS 100-1988) to determine the peak forces, 0.47-0.89N; displacements prior to the "breakaway" force that acknowledges key registration, 2.0-2.5 mm; and total key travel, 3.3-4.3 mm. Second, keyboard reaction forces were recorded while 10 subjects typed 4 alphanumeric sentences on the keyboards. It was found that the peak forces corresponding to each keystroke were 2.5 to 3.9 times the required activation forces, indicating that the subjects consistently displaced the keys to their limits. The average of the peak forces for all keystrokes was lowest for the keyboard with the lowest required activation force. It was concluded that keyboard reaction forces can be used as an index of finger forces for keying tasks. Further studies are necessary to evaluate the relationship between keyboard reaction forces, fatigue, and chronic muscle, tendon, and nerve disorders.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/15428119491019230 | DOI Listing |
Front Bioeng Biotechnol
January 2025
MGM Centre of Human Movement Science, MGM School of Physiotherapy, MGM Institute of Health Sciences, Navi Mumbai, India.
Purpose: Pelvic and hip motion are pivotal in maintaining postural control and energy efficient gait. An insight into influence of age and gender on the coupled motion of hip and pelvis in gait-cycle will guide clinical rehabilitation strategies and pertinent technology-design for specific age-groups. Therefore, present study evaluated pelvic and hip-joint gait kinematics in healthy females and males across adult-hood.
View Article and Find Full Text PDFHeliyon
January 2025
Institute of Metal Research (IMR), Chinese Academy of Science, Wenhua Road, Shenyang, China.
Recently, researchers have used silver nanoparticles (AgNPs) coupled with humic acid (HA) as antimicrobial agents. Herein, AgNPs were prepared and coupled with humic acid for their antimicrobial activities. The as-prepared AgNPs coupled with humic acid (HA) were characterized by an atomic force microscope (AFM), X-ray powder diffraction (XRD), zeta potential, zeta sizer, Fourier-transform infrared (FT-IR) spectroscopy, and UV-VIS spectrophotometer.
View Article and Find Full Text PDFJ Foot Ankle Surg
January 2025
Enovis Foot & Ankle, Atlanta, GA; Georgia Institute of Technology, Atlanta, GA. Electronic address:
Orthopedic screws are widely used to achieve bone reduction, compression, and construct stability. However, the relationship between insertion torque, interfragmentary compression, and fixation strength, especially when comparing standard screws with NiTiNOL/sustained dynamic compression (SDC), has not been thoroughly investigated. This study measured insertion torque, interfragmentary compression, and fixation strength for two types of headed orthopedic devices-standard and SDC-using solid foam bone replicates and cadaver validation.
View Article and Find Full Text PDFJ Sci Med Sport
January 2025
Department of Health Promotion, School of Public Health, Faculty of Medical and Health Sciences, Sylvan Adams Sports Institute, Tel-Aviv University, Israel. Electronic address:
Objectives: The study aimed to examine the effects of exercise-induced muscle damage on running kinetics.
Design: Twenty-six adult recreational male runners performed 60 min of downhill running (-10 %) at 65 % of maximal heart rate. Running gait changes, systemic and localized muscle damage markers were assessed pre - and post-exercise induced muscle damage protocol.
Polymers (Basel)
January 2025
Department of Mechanical Engineering, Faculty of Engineering, University of Porto, 4200-465 Porto, Portugal.
Smart textiles provide a significant technological advancement, but their development must balance traditional textile properties with electronic features. To address this challenge, this study introduces a flexible, electrically conductive composite material that can be fabricated using a continuous bi-component extrusion process, making it ideal for sensor electrodes. The primary aim was to create a composite for the filament's core, combining multi-walled carbon nanotubes (MWCNTs), polypropylene (PP), and thermoplastic elastomer (TPE), optimised for conductivity and flexibility.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!