A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The accuracy of power-spectrum analysis of heart-rate variability from annotated RR lists generated by Holter systems. | LitMetric

The accuracy of power-spectrum analysis of heart-rate variability from annotated RR lists generated by Holter systems.

Physiol Meas

Department of Biomedical Engineering, Clinica del Lavoro Foundation, IRCCS, Medical Centre of Rehabilitation, Montescano, Italy.

Published: May 1994

The accuracy of spectral analysis of heart-rate variability performed on annotated RR interval lists obtained from several commercial Holter systems was appraised. Five tape-recorder-based systems (Del Mar 750, Marquette 8000, Oxford Medilog Excel, Remco Cardioline AD 35 and Reynolds Pathfinder PA3) and four solid-state systems (Hewlett Packard 43420B, Marquette Seer, Oxford 6000FD2, Reynolds E-Ram) were considered. Two ECG signals with fixed real morphology but characterized by a different degree of modulation of the RR interval (reduced and normal variability) were fed into the recorders evaluated. The total power and the power in the very low-, low- and high-frequency bands were then estimated on all Holter-generated RR sequences. Spectral analysis was performed by both the autoregressive and fast-Fourier-transform methods. The estimation error of each parameter was statistically characterized and, for tape-recorder-based systems, inferential analysis was used to test for differences between recorders, tapes and times of recording. The centre and dispersion of the estimation error changed markedly from system to system. Some tape-recording systems showed large inter-recorder differences. The degree of spectral distortion was never uniform among selected bands. Solid-state systems performed better than tape-recording ones but both were limited in the accuracy by the quantization of RR interval measurement. The fast Fourier method yielded spectral estimates more stable than the autoregressive method. Our data clearly show that spectral analysis of very low-variability signals may be seriously affected by Holter recording and preprocessing of ECG signals.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0967-3334/15/2/006DOI Listing

Publication Analysis

Top Keywords

spectral analysis
12
analysis heart-rate
8
heart-rate variability
8
holter systems
8
tape-recorder-based systems
8
solid-state systems
8
ecg signals
8
estimation error
8
systems
7
analysis
5