In vitro and in vivo studies have shown both an inhibition and an activation of platelets after thrombolysis in acute myocardial infarction. Plasma beta-thromboglobulin, a marker of platelet activity, was evaluated daily during the first week after myocardial infarction in 24 patients who received intravenous streptokinase (group 1) and 26 who did not (group 2). On admission, levels of beta-thromboglobulin, as compared to those in healthy subjects (35 +/- 9 IU/ml), were similarly augmented in group 1 (105 +/- 27 IU/ml) and in group 2 (115 +/- 30 IU/ml); 3 hours later, values averaged 191 +/- 58 IU/ml in group 1 (p < 0.001 vs baseline) and 95 +/- 28 IU/ml in group 2 (not significant vs baseline; p < 0.001 between the two groups). From the second to the seventh day, beta-thromboglobulin augmented in those patients in both groups with postinfarction angina. From day 5 to day 7, patients of group 1 without angina had lower beta-thromboglobulin levels than patients of group 2 who had no symptoms. The lowest levels of platelet activity were observed in group 1 reperfused patients. These data indicate that in myocardial infarction an early platelet activation takes place that is enhanced by thrombolytic treatment; recurrence of angina is associated with persistent activation; in the absence of recurrent angina, thrombolysis can limit late platelet activation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0002-8703(94)90619-xDOI Listing

Publication Analysis

Top Keywords

+/- iu/ml
20
myocardial infarction
16
iu/ml group
12
group
9
week myocardial
8
platelet activity
8
patients group
8
platelet activation
8
beta-thromboglobulin
5
patients
5

Similar Publications

Compact all-fiber quantum-inspired LiDAR with over 100 dB noise rejection and single photon sensitivity.

Nat Commun

September 2023

The Edward S. Rogers Department of Electrical and Computer Engineering, University of Toronto, 10 King's College Road, Toronto, ON, M5S 3G4, Canada.

Entanglement and correlation of quantum light can enhance LiDAR sensitivity in the presence of strong background noise. However, the power of such quantum sources is fundamentally limited to a stream of single photons and cannot compete with the detection range of high-power classical LiDAR transmitters. To circumvent this, we develop and demonstrate a quantum-inspired LiDAR prototype based on coherent measurement of classical time-frequency correlation.

View Article and Find Full Text PDF

Non-local effects have the potential to radically move forward quantum enhanced imaging to provide an advantage over classical imaging not only in laboratory environments but practical implementation. In this work, we demonstrate a 43dB higher signal-to-noise ratio (SNR) using a quantum enhanced LiDAR based on time-frequency entanglement compared with a classical phase-insensitive quantum imaging system. Our system can tolerate more than 3 orders of magnitude higher noise than classical single-photon counting quantum imaging systems before detector saturation with a detector dead time of 25ns.

View Article and Find Full Text PDF

This Letter presents, to the best of our knowledge, the first report of a narrow-linewidth ∼790-800 edge-emitting semiconductor distributed feedback Bragg reflection waveguide diode laser (). The were fabricated using a ridge waveguide structure with 5th order, surface-etched grating forming the wavelength selective element. Unbonded devices with a 500 µm cavity length exhibited continuous wave threshold currents in the region of 25 mA with an output power of 2.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!