Analytic stereophotogrammetry and an interactive computer graphics program were used to obtain first order assessments of joint contact patterns in patellofemoral and glenohumeral joints, simulating normal and abnormal articulations. Precise (90 microns accuracy) computer graphic representations of the humeral head, glenoid, patella, and femoral articular surfaces were obtained from cadaver knees and shoulders. These surface representations were then manipulated into an articulated position, and joint contact areas computed by a proximity criterion. Pathologic states were then simulated, and contact recomputed. Simulated glenohumeral subluxations dramatically reduced contact area, and focused it eccentrically on the glenoid rim. Simulated size mismatch of humeral heads to glenoids reduced contact area, producing a pattern of peripheral contact on the glenoid if the humeral head had a larger radius of curvature, and central contact on the glenoid if the humeral head had a smaller radius of curvature. At 30 degrees knee flexion, the patellofemoral joint demonstrated a broad distribution of contact along the distal aspect of the patella and proximal aspect of the trochlea. Simulated lateral tilt (5 degrees) and translation (5 mm) of the patella resulted in shift of the predominant contact area laterally, along with a drastic decrease in the contact area. These results have implications for prosthetic sizing and biomechanical modeling of the glenohumeral and patellofemoral joints, and in selecting models for more rigorous empiric studies of joint contact. Furthermore, this technique allows a first order assessment of the effects of specific surgical reconstructions on articular mechanics.

Download full-text PDF

Source

Publication Analysis

Top Keywords

contact area
16
contact
12
joint contact
12
humeral head
12
glenohumeral patellofemoral
8
reduced contact
8
contact glenoid
8
glenoid humeral
8
radius curvature
8
computer simulation
4

Similar Publications

Background: To evaluate the associations between anatomical changes and visual outcomes after membrane peeling in eyes with different stages of idiopathic epiretinal membrane (iERM) using optical coherence tomography angiography (OCTA).

Methods: All iERM eyes were graded into four stages based on the presence of ectopic inner foveal layers (EIFL) and underwent 23-gauge vitrectomy combined with ERM and internal limiting membrane (ILM) peeling, while their fellow eyes were treated as the control group. OCTA was used to measure retinal thickness(RT), foveal avascular zone (FAZ)-related parameters and superficial and deep capillary plexus (SCP and DCP) layers using 6 × 6 mm scans before, 1 month and 3 months after surgery.

View Article and Find Full Text PDF

In the present study, porcine-derived collagen type I was covalently immobilized on the surface of titanium (Ti) implants via carboxyl groups introduced by bonded p-vinylbenzoic acid to investigate its in vitro biocompatibility with gingival stem cells and in vivo bone regeneration behavior in the edentulous ridges of Lanyu small-ear pigs at weeks 2 and 6 (short-term effectiveness) through micro-computed tomography and histological analysis. Analytical results found that gingival stem cells showed effective adhesion and spreading on these collagen-immobilized implant surfaces. After 2 and 6 weeks of healing, significant differences in Hounsfield units were observed among the control (week 2 (674.

View Article and Find Full Text PDF

Biomechanical evaluation of strength and stiffness of 2.0 mm and 1.5 mm locking plates with various screw configurations on rabbit tibias.

Res Vet Sci

January 2025

United States Military Academy, Department of Chemistry and Life Science, West Point, NY, United States of America.

Objective: The objective of this study was to compare the strength and stiffness of 1.5 mm and 2.0 mm locking plates with various screw fixation configurations applied to the tibia bones of rabbits.

View Article and Find Full Text PDF

Dropwise condensation offers substantial heat transfer advantages over filmwise condensation, enhancing the industrial condenser efficiency and reducing energy losses. However, the dynamics of condensate droplets on horizontal tube bundles remains complex and insufficiently studied. This paper presents a detailed investigation of the impact of dynamic behaviors of condensate droplets by numerical simulation using the Volume of Fluid model.

View Article and Find Full Text PDF

Background: Clinical feedback is often lacking in prehospital care, and while performance data is increasingly available to clinical and operational leadership, it is seldom made available to care providers themselves. In this study, we investigate the impact of a simple intervention consisting of the provision of monthly feedback reports via email to emergency medical dispatch nurses in three Swedish regions.

Method: Individualised reports consisting of 14 measures divided into descriptive (eg, priority-setting and call times), process (eg, dispatch times and documentation completeness) and outcome (eg, over/under triage rate) categories were developed with staff and management input.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!