Coronary artery calcification: assessment with electron beam CT and histomorphometric correlation.

Radiology

Department of Diagnostic Radiology, Clinical Center, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD 20892.

Published: September 1994

Purpose: To assess the reliability of electron beam computed tomography (CT) in the detection of calcific deposits in coronary arteries.

Materials And Methods: The authors quantitatively evaluated a total of 4,298 segments of coronary arteries with electron beam CT and histomorphometry.

Results: Regression analysis of the electron beam CT calcium score versus histomorphometric calcium area produced an r2 value of .92 (r = .96; P < .0001). Ninety-three percent (78 of 84) of all coronary arteries with stenosis of 76%-100% contained calcific deposits, and 20% (17 of 83) of all coronary arteries with stenosis of 0%-50% contained calcific deposits.

Conclusion: The amount of calcific deposits detected with electron beam CT correlates highly with histomorphometric measurements. Also, the amount of calcific deposits correlates well with the degree of coronary artery stenosis. Electron beam CT, therefore, is a promising noninvasive technique that can help depict the presence and extent of atherosclerotic plaques.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiology.192.3.8058924DOI Listing

Publication Analysis

Top Keywords

electron beam
24
calcific deposits
16
coronary arteries
12
coronary artery
8
arteries stenosis
8
contained calcific
8
amount calcific
8
coronary
6
electron
6
beam
6

Similar Publications

Ion beam induced secondary electron tomography of acrylonitrile-styrene-acrylate/polycarbonate polymer blends for fused filament fabrication and injection moulding.

Sci Rep

January 2025

Departamento de Ciencia de los Materiales e Ingeniería Metalúrgica y Química Orgánica, IMEYMAT, Universidad de Cádiz, Campus Río San Pedro, 11510, Puerto Real, Cádiz, Spain.

Polymer blending is an interesting strategy to broaden the combination of properties available for a variety of applications. To understand the behaviour of the new materials obtained as well as the influence of the fabrication parameters used, methods to analyse the distribution of polymers in the blend with resolution below the micrometer are required. In this work, we demonstrate the capability of focused ion beam (FIB) tomography to provide 3D information of the polymer distribution in objects obtained by blending acrylonitrile-styrene-acrylate (ASA) with polycarbonate (PC) (50 wt%), fabricated by Fused Filament Fabrication (FFF) and by Injection Moulding (IM).

View Article and Find Full Text PDF

Laser Wakefield Acceleration of Ions with a Transverse Flying Focus.

Phys Rev Lett

December 2024

Stanford University, Department of Mechanical Engineering, Stanford, California 94305, USA.

The extreme electric fields created in high-intensity laser-plasma interactions could generate energetic ions far more compactly than traditional accelerators. Despite this promise, laser-plasma accelerator experiments have been limited to maximum ion energies of ∼100  MeV/nucleon. The central challenge is the low charge-to-mass ratio of ions, which has precluded one of the most successful approaches used for electrons: laser wakefield acceleration.

View Article and Find Full Text PDF

The Linac Coherent Light Source (LCLS) is the world's first x-ray free electron laser. It is a scientific user facility operated by the SLAC National Accelerator Laboratory, at Stanford, for the U.S.

View Article and Find Full Text PDF

The concept of inert matrix fuel (IMF) has been proposed to utilize the energetic value of Pu and transmute minor actinides in nuclear reactors. In order to offset the initial reactivity of nuclear fuel, gadolinium (Gd) is employed as a burnable poison, owing to its high neutron absorption cross-section. To gain insights into the radiation stability and influence of grain boundaries on irradiation behaviour, 5 mol% Gd-doped ceria samples, sintered at varying temperatures, were subjected to irradiation using 400 Kr ions.

View Article and Find Full Text PDF

Terahertz reconfigurable intelligent surfaces (RIS) stand out from conventional phased arrays thanks to their unique electromagnetic properties and intelligent interconnect paradigms. They are a vital technology for terahertz wireless communication and radar detection systems. Compared with 1-bit coding metasurfaces, 2-bit coding metasurfaces offer significant advantages such as single beam steering and reduced quantization errors.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!