Flexible implant arthroplasty of the PIP joint in post-traumatic disorders can have very successful long-term results provided that the recommended surgical indications, operative techniques, and postoperative rehabilitation programs are carefully adhered to. Stability of the collateral ligament system and integrity of the extensor and flexor mechanism are essential prerequisites. A central slip splitting, central slip sparing, and palmar approach are described. The latter is preferred in post-traumatic conditions provided that the extensor mechanism is intact.
Download full-text PDF |
Source |
---|
Nat Commun
January 2025
Department of Biomedical Engineering and the Institute of Materials Science, University of Connecticut, Storrs, CT, 06269, USA.
Wearable and implantable bioelectronics that can interface for extended periods with highly mobile organs and tissues across a broad pH range would be useful for various applications in basic biomedical research and clinical medicine. The encapsulation of these systems, however, presents a major challenge, as such devices require superior barrier performance against water and ion penetration in challenging pH environments while also maintaining flexibility and stretchability to match the physical properties of the surrounding tissue. Current encapsulation materials are often limited to near-neutral pH conditions, restricting their application range.
View Article and Find Full Text PDFJ Arthroplasty
January 2025
Georgetown University School of Medicine, MedStar Georgetown University Hospital, Washington, D.C, USA. Electronic address:
Introduction: As the number of revision total knee arthroplasties (rTKA) continues to rise, there is increasing interest in the use of contemporary rotating hinge prostheses. These devices often incorporate porous cones to fill bone defects and enhance long-term fixation. This study evaluated the clinical and functional outcomes and survivorship in rTKA patients utilizing a rotating hinge prosthesis with flexible titanium (FT) cones, porous tantalum (PT) cones, or no cones.
View Article and Find Full Text PDFBiosensors (Basel)
January 2025
Faculty of Civil Engineering and Mechanics, Kunming University of Science and Technology, Kunming 650500, China.
Continuous glucose monitoring based on the minimally invasive implantation of glucose sensor is characterized by high accuracy and good stability. At present, glucose concentration monitoring based on fluorescent glucose capsule sensor is a new development trend. In this paper, we design a fluorescent glucose capsule sensor with a design optimization study.
View Article and Find Full Text PDFBioengineering (Basel)
January 2025
Department of Pathology, College of Veterinary Medicine, The University of Georgia, Athens, GA 30602, USA.
Three-dimensional printing was introduced in the 1980s, though bioprinting started developing a few years later. Today, 3D bioprinting is making inroads in medical fields, including the production of biomedical supplies intended for internal use, such as biodegradable staples. Medical bioprinting enables versatility and flexibility on demand and is able to modify and individualize production using several established printing methods.
View Article and Find Full Text PDFEur J Med Res
January 2025
National Center for Orthopaedics, Shanghai Sixth People's Hospital, 600 Yishan Road, Xuhui District, Shanghai, 200233, China.
Background: Scarf osteotomy is a well-established procedure for hallux valgus, yet recurrence rates range from 3.6% to 10%. Pes planus, which often coexisting with hallux valgus, is a risk factor for recurrence.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!