We examined the accuracy and feasibility of using simultaneous intracoronary Doppler and two-dimensional (2D) ultrasound imaging in the measurement of volumetric coronary blood flow (CBF). A femoral artery-to-circumflex coronary artery shunt was created in four dogs with tubing that incorporated an in-line transit-time ultrasound (TTU) flow probe. A 2D ultrasound catheter was introduced over a 0.014-inch Doppler guide wire into the circumflex artery with the guide wire tip positioned 2 cm beyond the imaging catheter tip. Cross-sectional area (CSA) and average peak velocity (APV) were recorded. CBF was determined from the previously validated relation CBF = CSA x 0.5 APV and the adjusted measurement formula CBF = CSA x 0.47 APV. Within the 119 measurements made, TTU CBF varied from 31 to 385 ml/min. An excellent correlation was found between 2D/Doppler-derived and TTU CBF with both constants; measurement agreement was improved and bias minimal with the 0.47 constant (slope = 0.9997; r = 0.99; p < 0.0001; SEE = -6.7 +/- 8.6). We conclude that simultaneous 2D and Doppler ultrasound yields accurate estimates of volumetric CBF.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0002-8703(94)90474-xDOI Listing

Publication Analysis

Top Keywords

measurement volumetric
8
volumetric coronary
8
coronary blood
8
blood flow
8
doppler ultrasound
8
guide wire
8
cbf csa
8
ttu cbf
8
cbf
7
ultrasound
5

Similar Publications

A morphometric analysis of the cranial base in trigonocephaly.

J Craniomaxillofac Surg

January 2025

Department of Clinical Anatomy, School of Laboratory Medicine and Medical Sciences, University of KwaZulu-Natal, Durban, South Africa. Electronic address:

Trigonocephaly occurs when the metopic suture fuses prematurely. Few studies have documented the morphometry of the entire anterior cranium in trigonocephaly and not on the morphometric changes to the cranial fossae alone. Thus, this study aimed to determine and compare the dimensions of the anterior cranial fossa (ACF) in trigonocephaly and control groups.

View Article and Find Full Text PDF

Background: The long-term stability of allograft or native bone in facial vascularized composite allograft (fVCA) recipients is unclear. This study quantified long-term bone volume changes in facial transplants.

Methods: Computed tomography scans of eight fVCA recipients (2011-2023) were analyzed with Materialise Mimics.

View Article and Find Full Text PDF

Introduction: Ultrasound imaging (US) is the method of choice to assess the canine prostate gland. Whilst recent studies have documented the role of castration in the development of prostatic neoplasia, little is known about parenchymal and perfusion features of the normal and abnormal prostate in neutered dogs. No data are available concerning prostatic changes after the first 90 days following castration.

View Article and Find Full Text PDF

Bone imaging modality precision and agreement between DXA, pQCT, and HR-pQCT.

JBMR Plus

February 2025

Department of Medicine, School of Clinical Sciences at Monash Health, Monash University, Clayton, VIC 3168, Australia.

Quantifying precision error for DXA, peripheral QCT (pQCT), and HR-pQCT is crucial for monitoring longitudinal changes in body composition and musculoskeletal outcomes. Agreement and associations between bone variables assessed using pQCT and second-generation HR-pQCT are unclear. This study aimed to determine the precision of, and agreement and associations between, bone variables assessed via DXA, pQCT, and second-generation HR-pQCT.

View Article and Find Full Text PDF

Background: With increasing evidence supporting three-dimensional (3D) automated breast (AB) ultrasound (US) for supplemental screening of breast cancer in increased-risk populations, including those with dense breasts and in limited-resource settings, there is an interest in developing more robust, cost-effective, and high-resolution 3DUS imaging techniques. Compared with specialized ABUS systems, our previously developed point-of-care 3D ABUS system addresses these needs and is compatible with any conventional US transducer, which offers a cost-effective solution and improved availability in clinical practice. While conventional US transducers have high in-plane resolution (axial and lateral), their out-of-plane resolution is constrained by the poor intrinsic elevational US resolution.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!