The commercial availability of Tc-99m-labeled myocardial perfusion agents had added choices in the noninvasive clinical assessment of coronary artery disease. Preferential use of Tc-99m sestamibi has been advocated principally due to improved image quality, which results from the combined physical and biological characteristics of this agent. This article reports upon the investigation of another approach for Tc-99m sestamibi SPECT--dual-isotope rest-stress myocardial perfusion SPECT, which takes advantage of the Anger camera's ability to collect date in different energy windows. For the dual-isotope approach, separate radiopharmaceuticals are employed for the rest injection and the stress injection.

Download full-text PDF

Source

Publication Analysis

Top Keywords

myocardial perfusion
12
tc-99m sestamibi
12
perfusion spect
8
dual-isotope myocardial
4
spect rest
4
rest thallium-201
4
thallium-201 stress
4
stress tc-99m
4
sestamibi commercial
4
commercial availability
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!