A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Sensitometric and archival evaluation of Kodak RA films in dental automatic processing. | LitMetric

The Kodak Rapid Access System is an extension of the T-grain technology (T-Mat film). Unlike the T-Mat film, the T-Mat/Rapid Access film is forehardened by the addition of more hardener to the film emulsion. It can thus be processed rapidly in a Kodak Rapid Access medical processor in only 45 seconds dry-to-dry cycle by using the Kodak X-Omat RA/30 developer that does not contain a hardener. The absence of the hardener, glutaraldehyde, in the developer also makes this solution environmentally safer. In medical radiography, the T-Mat film has been replaced by the T-Mat/Rapid Access film. However, in dental extraoral radiography the T-Mat film is still being used because the processing solutions and the comparatively low temperatures of dental automatic processors are different from those used in medical radiography. This report shows that, for panoramic and other dental extraoral radiography, T-Mat films can be replaced by T-Mat/RA films by processing them in conventional Kodak X-Omat RP solutions using a dental automatic processing cycle. The differences in the sensitometric properties of the T-Mat and T-Mat/rapid Access films were negligible and therefore clinically insignificant. All films tested well for archival quality.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0030-4220(94)90208-9DOI Listing

Publication Analysis

Top Keywords

t-mat film
16
dental automatic
12
t-mat/rapid access
12
radiography t-mat
12
automatic processing
8
kodak rapid
8
rapid access
8
access film
8
kodak x-omat
8
medical radiography
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!