In this paper the impact of hemapheresis technology on 238 allogeneic bone marrow transplants performed in Pescara from 1982 through 1993 is described. Granulocyte transfusions were limited to patients with neutrophil level < 0.2 x 10(9)/L. An average of 4 units of packed red blood cells were required to maintain adequate hemoglobin levels. Patients with major ABO incompatibility showed an increased requirement of red blood cell support as compared to patients ABO-matched and ABO minor mismatched. For platelet support single-donor platelets collected on a blood-cell separator were given. A total of 1548 platelet transfusions were examined. The median number of platelet transfusions for each patient was 5. Platelet refractoriness occurred in 44% of patients. The hemorrhage related mortality was 0.9%. The advancement made in the field of hemapheresis technology, as well as the improved transplant technique, have contributed to increase the post-transplant survival from 17% in the early experience (1976-1982) to 88% in the recent years (1992-1993).
Download full-text PDF |
Source |
---|
Nat Commun
January 2025
Center for Engineering in Medicine and Surgery, Massachusetts General Hospital and Harvard Medical School, Boston, MA, 02114, USA.
Circulating Tumor Cells (CTCs) in blood encompass DNA, RNA, and protein biomarkers, but clinical utility is limited by their rarity. To enable tumor epitope-agnostic interrogation of large blood volumes, we developed a high-throughput microfluidic device, depleting hematopoietic cells through high-flow channels and force-amplifying magnetic lenses. Here, we apply this technology to analyze patient-derived leukapheresis products, interrogating a mean blood volume of 5.
View Article and Find Full Text PDFJ Extra Corpor Technol
December 2024
Physiology Research Center, Iran University of Medical Sciences, Tehran 1449614535, Iran.
Introduction: Myocardial protection with cardioplegia is a crucial approach to mitigate myocardial damage during coronary bypass grafting surgery (CABG) with cardiopulmonary bypass (CPB). The major component of the del Nido cardioplegia solution, Plasma-Lyte A, is difficult to obtain in Iran due to high cost. The objective of the current study was to study if the lactated Ringer's solution as the base for del Nido solution (LR DN) usage is a viable option as a substitute for Plasma-Lyte A in adult patients presenting for CABG surgery.
View Article and Find Full Text PDFTalanta
March 2025
Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan, Queensland, 4111, Australia; School of Engineering and Built Environment, Griffith University, Nathan, Queensland, 4111, Australia. Electronic address:
Anal Methods
December 2024
School of Instrumentation and Optoelectronic Engineering, Precision Opto-Mechatronics Technology Key Laboratory of Education Ministry, Beihang University, Beijing, China.
PPG signals are a new means of non-invasive detection of blood glucose, but there are still shortcomings of poor time adaptability and low prediction accuracy of blood glucose quantitative models. Few studies discuss prediction accuracy in the case of a large time interval span between modeling and prediction. This paper proposes an automatic optimal threshold baseline removal algorithm based on variational mode decomposition (AOT-VMD), which can adaptively eliminate high-frequency noise and baseline interference for each decomposed IMF modal component and reduce the baseline difference of PPG signals from different days.
View Article and Find Full Text PDFTransfusion
December 2024
Vitalant Research Institute, Denver, Colorado, USA.
Background: Pathogen reduction technology (PRT)-treated apheresis platelets (APs) were returned without platelet swirl and with pH < 6.2. The platelet donor was taking prescription levothyroxine and metformin plus over-the-counter medications and supplements.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!