A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Performance of an intravenous gas exchanger (IVOX) in a venovenous bypass circuit. | LitMetric

To analyze quantitatively the performance of the intravenacaval blood gas exchanger (IVOX), we developed a right atrium-pulmonary artery venovenous extracorporeal bypass circuit. Oxygen transfer and carbon dioxide removal were calculated at different blood flow rates, different hemoglobin levels, and during permissive hypercapnia. Oxygen transfer increased linearly with blood flow up to 41 mL/min. Likewise, O2 transfer increased linearly with hemoglobin levels up to 7.5 g/dL, but no further increases were achieved above this level. Carbon dioxide removal increased linearly as flow increased from 1.0 to 3.0 L/min but did not increase further for higher flows. Carbon dioxide removal was 45 mL/min at blood carbon dioxide tension of 42 mm Hg but increased to a maximum of 81 mL/min at a carbon dioxide tension of 90 mm Hg. We conclude that IVOX is a diffusion-limited device dependent on blood flow, hemoglobin content, and the gas pressure gradient across the membrane. Further engineering improvements are needed to improve the gas exchange performance of IVOX.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0003-4975(94)90105-8DOI Listing

Publication Analysis

Top Keywords

carbon dioxide
20
dioxide removal
12
blood flow
12
increased linearly
12
gas exchanger
8
exchanger ivox
8
bypass circuit
8
oxygen transfer
8
hemoglobin levels
8
transfer increased
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!