In the method of constant stimuli applied to measuring heartbeat detection, subjects judge the simultaneity of heartbeats and exteroceptive comparison stimuli presented at various intervals after the R-wave (0, 100, 200, 300, 400, and 500 ms). Using versions of this procedure, investigators have found that between 20% (Yates, Jones, Marie, & Hogben, 1985) and 54% (Brener, Liu, & Ring, 1993) of subjects can detect heartbeat sensations. Whereas Yates et al. used a single comparison stimulus on each trial and Brener et al. used 10, the present study examined whether this disparity in heartbeat detection performance could be attributed to the number of comparison stimuli presented on each trial. In each of 360 trials, 30 subjects judged the simultaneity of heartbeat sensations and tones following 1, 5, or 10 comparison stimulus presentations. Significantly fewer subjects met the criterion for heartbeat detection with 1 tone presentation (13%) than with either 5 (43%) or 10 (47%) tone presentations. It is concluded that a single stimulus presentation imposes data limitations that result in underestimation of the accuracy of heartbeat detection. The presentation of at least 5 stimuli in each trial alleviates this limitation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1469-8986.1994.tb02219.x | DOI Listing |
J Perinat Neonatal Nurs
January 2025
Author Affiliations: Departments of Midwifery (Mr Fikadu), Internal Medicine (Dr Shibru), and Obstetrics and Gynecology (Drs Koira, Chufamo, and Mulugeta), and School of Public Health (Messrs Kote and Hailemariam and Dr Ayele), College of Medicine and Health Sciences, Arba Minch University, Southern Region, Arba Minch, Ethiopia; Ethiopia Midwives Association, Addis Ababa, Ethiopia (Messrs Belgu and Mazengia); and Institute of Public Health, College of Medicine and Health Sciences, University of Gondar, Amhara Region, Gondar, Ethiopia (Dr Ayele).
Purpose: This study was aimed to assess the effect of intermittent fetal heart rate (FHR) monitoring using Moyo Doppler compared with fetoscope in hospitals of Ethiopia, 2023.
Background: To facilitate more prompt identification of a hypoxic fetus, Laerdal Global Health has recently introduced the Moyo FHR monitor. Nevertheless, there exists limited knowledge regarding its efficacy derived from multicenter contextual trials conducted in resource-constrained environments, specifically in Ethiopia.
Eur J Med Res
January 2025
The Department of Pediatrics, The Third Xiangya Hospital of Central South University, Changsha, 410013, Hunan, China.
Background: The systemic immune-inflammation index (SII) is an emerging marker of inflammation, and the onset of psoriasis is associated with inflammation. The aim of our study was to investigate the potential impact of SII on the incidence rate of adult psoriasis.
Methods: We conducted a cross-sectional study based on the National Health and Nutrition Examination Survey (NHANES) 2011-2014 data sets.
J Clin Monit Comput
January 2025
Department of Electrical Engineering, Eindhoven University of Technology, Groene Loper 3, 5612 AZ, Eindhoven, the Netherlands.
Unobtrusive pulse rate monitoring by continuous video recording, based on remote photoplethysmography (rPPG), might enable early detection of perioperative arrhythmias in general ward patients. However, the accuracy of an rPPG-based machine learning model to monitor the pulse rate during sinus rhythm and arrhythmias is unknown. We conducted a prospective, observational diagnostic study in a cohort with a high prevalence of arrhythmias (patients undergoing elective electrical cardioversion).
View Article and Find Full Text PDFJACC Clin Electrophysiol
January 2025
Cardioangiologisches Centrum Bethanien, Agaplesion Markus-Krankenhaus, Frankfurt am Main, Germany.
Background: The net benefit of oral anticoagulation in patients with end-stage renal disease on hemodialysis (HD) is uncertain. In recent years, left atrial appendage closure (LAAC) has emerged as an alternative to oral anticoagulation; however, there is scant evidence of LAAC in patients on HD.
Objectives: This study aimed to assess the feasibility and safety of LAAC in patients on HD.
Cochrane Database Syst Rev
January 2025
Department of Health Promotion and Policy, University of Massachusetts, Amherst, MA, USA.
Background: Electronic cigarettes (ECs) are handheld electronic vaping devices that produce an aerosol by heating an e-liquid. People who smoke, healthcare providers, and regulators want to know if ECs can help people quit smoking, and if they are safe to use for this purpose. This is a review update conducted as part of a living systematic review.