A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The development of a valveless cardiac assist device attached to the ventricular apex. | LitMetric

Konstantinov et al, in October, 1991, published a novel way to bridge a patient for heart transplantation. They proposed to cut off both ventricles high under the atrioventricular groove, leaving the atria, aorta, and pulmonary artery and their valves intact and to attach pneumatically driven, valveless pulsating pouches to assist the heart until a donor could be found. The removal of the ventricles just below the atrioventricular groove is called the "high cut"; it, however, destroys the chordae tendineae rendering the mitral and tricuspid valves insufficient. These have to be replaced by tissue inflow valves. We chose to cut off the ventricles at a lower level (the "low cut") to leave the papillary muscles on both sides intact, thereby saving the integrity of the mitral and tricuspid valves. Pulsating pouches were made to fit the heart at this lower level. They can be easily connected to the remaining heart after a specially disigned cuff has been sutured over the ventricular stumps. The pouches were pumped during the systole of the natural heart, but the myocardium may have to be electrically stimulated during systole to prevent undue distension. If the turgor is too weak to prevent distension, a sleeve over the ventricles is provided. To find the best location for these pouches, human cadaver implantations were done and the pre peritoneal cavity was found to be the most suitable. In vitro testing to determine how much flow could be pumped was done by attaching the pouches to fresh pig hearts and connecting them to a double sided mock circulation.(ABSTRACT TRUNCATED AT 250 WORDS)

Download full-text PDF

Source

Publication Analysis

Top Keywords

cut ventricles
8
atrioventricular groove
8
pulsating pouches
8
mitral tricuspid
8
tricuspid valves
8
lower level
8
heart
5
pouches
5
development valveless
4
valveless cardiac
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!