This study was undertaken to compare pressure half-time and continuity equation methods in the postoperative evaluation of anuloplasty rings. We performed 2-dimensional echocardiography and Doppler studies in 39 patients who had undergone valve repair for mitral regurgitation. In patients with a pressure half-time of 110 msec or more (9/39), there was no significant difference in calculated valve area between the 2 methods (p = 0.696). A significant difference was shown between the 2 methods (p < 0.001) in patients with a half-time less than 110 msec (30/39). When patients were classified according to the type of ring they had received, no significant difference was noted between the 2 groups with regard to peak and mean mitral gradients. In patients placed in subgroups according to half-times of less than 110 msec and half-times of 110 msec or more, no difference was noted between groups in terms of mean mitral gradient, presence of mitral regurgitation, left atrial size, left ventricular function, or heart rate. The continuity equation appears to provide much more homogeneous results in the calculation of valve area in patients who have undergone valvular repair for mitral valve regurgitation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC325163PMC

Publication Analysis

Top Keywords

110 msec
16
continuity equation
12
pressure half-time
12
evaluation anuloplasty
8
anuloplasty rings
8
patients undergone
8
repair mitral
8
mitral regurgitation
8
half-time 110
8
valve area
8

Similar Publications

Improving Real-Time Feedback During Cochlear Implantation: The Auditory Nerve Neurophonic/Cochlear Microphonic Ratio.

Ear Hear

January 2025

Department of Otorhinolaryngology and Head and Neck Surgery, Radboud University Medical Centre, Donders Institute for Brain, Cognition and Behaviour, Nijmegen, The Netherlands.

Objectives: Real-time monitoring of cochlear function to predict the loss of residual hearing after cochlear implantation is now possible. Current approaches monitor the cochlear microphonic (CM) during implantation from the electrode at the tip of the implant. A drop in CM response of >30% is associated with poorer hearing outcomes.

View Article and Find Full Text PDF

We consider avalanche photodiodes (APDs) functioning under near Geiger-mode operation for extremely weak light (single or several photons) detection, such as in LiDAR receivers. To meet such demands, APDs which simultaneously have a large active window size, moderate bandwidth (∼GHz), and high internal gain (responsivity), are highly desired. However, it is difficult to design APDs capable of meeting the afore-mentioned performance requirements due to the intrinsic limitations of the gain-bandwidth product (GBP).

View Article and Find Full Text PDF

Background: People aging with HIV (PAWH) experience greater impairment in physical and pulmonary function than individuals aging without HIV. We examined whether baseline physical function was associated with subsequent pulmonary impairments.

Methods: Associations of frailty and physical function (gait speed [m/sec], grip strength [kg]) with pulmonary function (< 80% predicted diffusing capacity for carbon monoxide [DL] and forced expiratory volume [FEV]) 3 years later were modeled; age, HIV status, and smoking were assessed as effect modifiers.

View Article and Find Full Text PDF

Deep Learning Assisted Classification of T1ρ-MR Based Intervertebral Disc Degeneration Phases.

J Magn Reson Imaging

July 2024

Shenzhen Key Laboratory of Bone Tissue Repair and Translational Research, Department of Orthopaedic Surgery, The Seventh Affiliated Hospital, Sun Yat-sen University, Shenzhen, China.

Background: According to the T1ρ value of nucleus pulposus, our previous study has found that intervertebral disc degeneration (IDD) can be divided into three phases based on T1ρ-MR, which is helpful for the selection of biomaterial treatment timing. However, the routine MR sequences for patients with IDD are T1- and T2-MR, T1ρ-MR is not commonly used due to long scanning time and extra expenses, which limits the application of T1ρ-MR based IDD phases.

Purpose: To build a deep learning model to achieve the classification of T1ρ-MR based IDD phases from routine T1-MR images.

View Article and Find Full Text PDF

Introduction: People with Parkinson's Disease (PD) show abnormal gait patterns compromising their independence and quality of life. Among all gait alterations due to PD, reduced step length, increased cadence, and decreased ground-reaction force during the loading response and push-off phases are the most common. Wearable biofeedback technologies offer the possibility to provide correlated single or multi-modal stimuli associated with specific gait events or gait performance, hence promoting subjects' awareness of their gait disturbances.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!