A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Laser coronary angioplasty. Critical analysis of the first patients]. | LitMetric

Purpose: To evaluate the success rate and complications, as well as the technical difficulties involved catheter laser coronary angioplasty, making evident the unsuccessful cases.

Methods: Twenty eight patients were treated with laser from August to November, 1993. The treatment was complemented with balloon angioplasty. Lesions were complex: 10 (36%) were type B and 18 (64%), type C. Concerning the obstruction grade, 18 (64%) were > or = 95%. Laser generator CVX 300(TM) Spectranectics as well as Extreme(TM) and Vitesse(TM) catheters with 1.4, 1.7 and 2.0mm in diameter, concentric and excentric, were used. Laser procedure success was defined as a reduction > 20% in the obstruction grade. The procedure success was attended when the residual stenosis was < 50% after a 15-minute observation, after balloon complementation.

Results: The unsuccess rate with laser catheter (Lc) was 34% (10 lesions) of which 3 cases were solved by other methods, 5 were not successful because of anatomic difficulties in surpassing the lesion and, in the two others the success criterium in the reduction of the obstruction grade of the coronary artery was not achieved, although the lesion surpassing was possible with the use of balloon catheter. The final success reached 89% (21 lesions). The procedure complications were a case of thrombosis, a perforation accompanied by a myocardial infarction and another myocardial infarction (non-Q wave), all with good outcome.

Conclusion: The use of laser in the treatment of coronary artery obstructive lesions is a viable method. Nonetheless, more experience is necessary to demonstrate its actual value, optimizate the results and may be reduce restenosis rate.

Download full-text PDF

Source

Publication Analysis

Top Keywords

obstruction grade
12
coronary angioplasty
8
procedure success
8
coronary artery
8
myocardial infarction
8
laser
6
success
5
[laser coronary
4
angioplasty critical
4
critical analysis
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!