The measurement of tremor using simple laser systems.

J Neurosci Methods

Department of Kinanthropology, University of Québec, Canada.

Published: July 1994

Quantification of movement pathologies is an important challenge of the clinical and research laboratories today. Basically, two problems must be addressed. The first one is to find the appropriate technology; the second is to develop adequate measures from the raw data which will best discriminate between health and pathology. In this paper, we propose a simple method to record and analyse tremor and other microdisplacements of the upper extremities based on the recording of position by laser analog sensors. Any microcomputer equipped to perform analog-digital conversion is compatible for use with this system. The performance of the laser system is examined and compared with the performance of accelerometers. Finally, data recorded with a laser analog sensor from a patient with Parkinson's disease and a control subject are presented. This new laser-based quantitative method may prove to be an important tool in early and differential diagnosis of neurodegenerative diseases of the central nervous system.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0165-0270(94)90143-0DOI Listing

Publication Analysis

Top Keywords

laser analog
8
measurement tremor
4
tremor simple
4
laser
4
simple laser
4
laser systems
4
systems quantification
4
quantification movement
4
movement pathologies
4
pathologies challenge
4

Similar Publications

Effects of high-intensity laser therapy in patients with De Quervain's tenosynovitis: A systematic review and meta-analysis.

J Hand Ther

January 2025

Physiotherapeutic Resources Research Laboratory, Department of Physical Therapy, Federal University of São Carlos (UFSCar), São Paulo, Brazil; Department of Rehabilitation Sciences, University of Hartford, West Hartford, CT, USA.

Background: De Quervain's tenosynovitis (QT) is common among individuals performing repetitive manual tasks and significantly affects daily activities due to pain. While traditional treatments often provide limited relief, high-intensity laser therapy (HILT) shows as a potential analgesic resource.

Purpose: This systematic review aimed to evaluate the analgesic effects of HILT in patients with QT.

View Article and Find Full Text PDF

Lauryl-NrTP6 lipopeptide self-assembled nanorods for nuclear-targeted delivery of doxorubicin.

Nanoscale

January 2025

Soft Matter Nanotechnology, Center for Cooperative Research in Biomaterials (CIC biomaGUNE), Basque Research and Technology Alliance (BRTA), Paseo de Miramon 194, 20014, Donostia-San Sebastián, Spain.

Targeted delivery offers solutions for more efficient therapies with fewer side effects. Here, lipopeptides (LPs) prepared by conjugation of the nuclear-targeting peptide analogue H-YKQSHKKGGKKGSG-NH (NrTP6) and two lauric acid chains are used to encapsulate the chemotherapeutic agent doxorubicin (DX) through a solvent-exchange protocol. LPs spontaneously form nanosized rod-like assemblies in phosphate buffer.

View Article and Find Full Text PDF

Numerous research studies have delved into the potential effect of LASER therapy on alleviating pain associated with plantar fasciitis. However, the distinct effects of both High Intensity and Low Intensity LASER therapy (HILT/LILT) on addressing plantar fasciitis pain have not been thoroughly investigated. This systematic review seeks to provide a comprehensive summary of the present body of literature regarding the use of LASER therapy in managing pain related to plantar fasciitis.

View Article and Find Full Text PDF

Can Low Structural Anisotropy Produce High Optical Anisotropy? Anomalous Giant Optical Birefringent Effect in PIAlI in Focus.

J Am Chem Soc

January 2025

Functional Crystals Lab, Key Laboratory of Functional Crystals and Laser Technology, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China.

Tetrahedral halides with broad transparency and large second harmonic effects have the potential to serve as mid-infrared wide-bandgap materials with balanced nonlinear-optical (NLO) properties. However, their regular tetrahedral motifs tend to exhibit low optical birefringence (Δ < 0.03) due to limited structural anisotropy, which constrains their practical phase-matched capability.

View Article and Find Full Text PDF

Comparing analog and 3D measurements of vertical dimension in edentulous subjects.

J Dent

January 2025

Clinic of General-, Special Care- and Geriatric Dentistry, Center for Dental Medicine, University of Zurich, Zurich, Switzerland; School of Dentistry, Federal University of Goiàs, Goiania, Brazil; Department of Reconstructive Dentistry, Division of Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.

Objective: This study aimed to explore the feasibility and reliability of measuring the vertical dimension of occlusion/rest (OVD/RVD) on 3D facial scans of edentulous patients.

Methods: Nineteen edentulous participants rehabilitated with complete removable dental prostheses (CDs) participated in this study. Analog measurements (control) were obtained directly on the face for each participant with the jaws positioned at the rest position (without CDs, RVD) and at central occlusion (OVD), between the facial landmarks: Glabella (G) and Soft Pogonion (SP), Pronasale (PN) and SP, and Subnasale (SN) and SP.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!