A randomized clinical trial was undertaken to compare the effectiveness of two partial denture designs, one with I-bar (bar) and the other with circumferential retainers (circumferential), in 134 patients with Kennedy class I and class II edentulous conditions. A total of 30 partial dentures were considered failures, five because of abutment failures and 25 because of the lack of removable partial denture use for eating. The 5-year success rate of 71.3% for the circumferential design did not differ significantly from the 76.6% for the bar design (p > 0.05). There were no discernible changes in the nine periodontal health components of abutment teeth with either of the two designs after 60 months. The results indicate that the two designs do not differ significantly in terms of success rates, maintenance care, and effects on abutment teeth. A well-constructed removable partial denture of either design, supported by favorable abutments and accompanied by a regular recall program offers a satisfactory treatment modality.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/0022-3913(94)90340-9 | DOI Listing |
J Contemp Dent Pract
October 2024
Department of Crown and Bridge, Faculty of Dentistry, Al-Azhar University, Cairo, Egypt.
Aim: To assess hard as well as soft peri-implant tissues within cases having two lost adjacent anterior teeth treated through placing either two implants with two separate crowns or only an implant along with a crown with a cantilever, and evaluating the effect of polyetheretherketone (PEEK) restoration on cantilever design up to 18 months after functional loading.
Materials And Methods: Twenty-seven participants (15 males and 12 females; mean age, 38.6 years; range 20-50 years) with missing two adjacent anterior teeth were treated with implant system (Flotecno implant system, Italy).
J Dent Sci
January 2025
School of Dentistry, Chung Shan Medical University, Taichung, Taiwan.
Background/purpose: The advent of digital technologies has significantly transformed the current dentistry, particularly in the fabrication of removable dental prostheses. A bibliometric analysis of literature may provide a direction of research hotspots and future trends in this field.
Materials And Methods: Data were retrieved from Web of Science database for the analysis of literature on digital technologies for removable dental prostheses.
J Dent
January 2025
Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine; Shanghai, 200011, China; College of Stomatology, Shanghai Jiao Tong University, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology, Shanghai Research Institute of Stomatology, Shanghai, 200011, China; Department of Stomatology, Fengcheng Hospital of Fengxian District, Shanghai, 201418, China. Electronic address:
Objectives: To compare the adaptation of maxillary removable partial denture (RPD) frameworks fabricated through direct digital workflows with that of traditional cast frameworks and indirect digital frameworks.
Methods: The workflow for fabricating the digital cobalt-chromium framework encompassed intraoral scanning (IOS) using Trios 3, computer-aided survey and design, and subsequently either the lost-wax technique from a printed resin framework pattern (Framework B) or direct selective laser melting (SLM) (Framework C). The traditional cast framework (Framework A) was selected as a control.
Polymers (Basel)
January 2025
Department of Advanced Prosthodontics, Institute of Science Tokyo, Tokyo 113-8510, Japan.
Light-polymerizing reline materials offer improved chairside workability compared to conventional auto-polymerizing reline materials, addressing the partial denture (RPD) incompatibility caused by residual ridge resorption owing to long-term use. This study evaluates the fitting accuracy of relined materials by combining conventional fitting tests with three-dimensional (3D) measurements for detailed analysis. Light-polymerizing reline material (HikariLiner, Tokuyama, Tokyo, Japan, LP) and auto-polymerizing material (Rebase III, Tokuyama, AP) were used.
View Article and Find Full Text PDFDent J (Basel)
January 2025
Department of Advanced Prosthodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, Tokyo 1138510, Japan.
Malnutrition is a significant concern for head and neck cancer (HNC) patients, as treatment often impairs mastication, causes dysphagia, and alters taste and smell, leading to reduced food intake and a diminished quality of life. Thus, this study aims to compare nutritional intake in HNC survivors using maxillofacial prostheses (MFPs) to healthy reference values and identify the factors influencing their dietary intake. The study included 56 patients treated for HNC undergoing rehabilitation with comfortable definitive dentures for over a month at the Maxillofacial Prosthetics Clinic of Tokyo Medical and Dental University Hospital.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!