A clinical study was undertaken to assess the influence of patient-related factors on wear of the socket in Charnley low-friction arthroplasty. One hundred nine arthroplasties in 79 patients were reviewed at an average of 10.3 years. A new method of activity assessment was designed and used to estimate the distance walked by each patient. This method was validated by a pedometer that recorded the time taken by each patient to walk 20 m. Activity level was related to the amount of movement at the level of the prosthetic articulation by calculating the sliding distance of a point at the center of the surface of the head of the femoral component. Wear was found to correlate with patient activity, but not with the physical characteristics of the patient or the time since operation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0883-5403(94)90042-6DOI Listing

Publication Analysis

Top Keywords

charnley low-friction
8
low-friction arthroplasty
8
activity
4
activity socket
4
socket wear
4
wear charnley
4
arthroplasty clinical
4
clinical study
4
study undertaken
4
undertaken assess
4

Similar Publications

Dr. John H. Charnley (1924-1982) revolutionized orthopedic surgery with his groundbreaking innovations in hip replacement with exceptional skill and a holistic thought process, which has had an impact to this day in the world of arthroplasty.

View Article and Find Full Text PDF

The McKee-Farrar hip prosthesis gained popularity in the 1960s and was one of the first widely used prostheses to employ a metal-on-metal design. Eventually, it laid the framework for the development of second and third-generation hip replacement prostheses. In time, the McKee-Farrar prosthesis was found to have high rates of early aseptic loosening and fell out of favor, especially with the development of the Charnley low-friction metal-on-polyethylene design.

View Article and Find Full Text PDF

Charnley's low-friction principle of total hip arthroplasty (THA) is recognized as the gold standard. However, complications may arise, and one of the major reasons for revising THA is dislocation. Under such a background, Pr.

View Article and Find Full Text PDF

In the 1960s, Sir John Charnley introduced to clinical practice his concept of low-friction total hip arthroplasty (THA). Although early designs were plagued by poor performance and even failure, there have been steady advances in implant designs, biomaterials, surgical techniques and an understanding of the biomechanical restoration of the hip; these advances have contributed to improvements in implant survival and clinical outcomes of THA in the past three decades. With improved wear resistance and mechanical reliability, a potential to last for at least 25 to 30 years are now available for THA.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!