A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3145
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determination of phenol in urine by high-performance liquid chromatography with on-line precolumn enzymatic hydrolysis of the conjugates. | LitMetric

A precolumn enzyme reactor containing beta-glucosidase immobilized on LC-NH2 packed-material beads was used on-line with HPLC for determining the glucuronide/sulphate metabolites of benzene. After dilution with phosphate buffer (pH 6.8), the urine sample was injected into the HPLC system directly. Subsequently, after hydrolysis of the conjugates, phenol was produced in the enzyme reactor and was separated from other urinary components on a reversed-phase C18 column with fluorescence detection. A switching valve assembly was used to control the passage of the sample and the eluent into the reactor to prevent damage to the enzyme by the elution solvent. Factors affecting the enzymatic hydrolysis were investigated. The proposed method provides a simple and rapid procedure for urinary phenol determination. The calibration graph was linear in the range 0.25-5.0 ppm with a good correlation coefficient (r = 0.999), and in the range 0.05-1.0 ppm with r = 0.981. The detection limit was 10 ppb and the relative standard deviation was less than 2.27%. Application of the method is illustrated by the analysis of a urine sample collected from a gas station worker.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0378-4347(94)00175-8DOI Listing

Publication Analysis

Top Keywords

enzymatic hydrolysis
8
hydrolysis conjugates
8
enzyme reactor
8
urine sample
8
determination phenol
4
phenol urine
4
urine high-performance
4
high-performance liquid
4
liquid chromatography
4
chromatography on-line
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!