Pitfalls in measuring peritoneal dialysis prescription.

Perit Dial Int

Baxter Clinical Engineering Lab, Minneapolis, Minnesota, 55404.

Published: December 1994

Download full-text PDF

Source

Publication Analysis

Top Keywords

pitfalls measuring
4
measuring peritoneal
4
peritoneal dialysis
4
dialysis prescription
4
pitfalls
1
peritoneal
1
dialysis
1
prescription
1

Similar Publications

Transthoracic echocardiography plays a crucial role in clinical diagnosis and is increasingly being used around the world. Comprehensive echocardiographic examinations require accurate measurements and the operators to have excellent technical skills. Despite the availability of several published echocardiographic guidelines, the absence of recommended operational manuals in daily practice has resulted in significant variation in the content of echocardiography reports across different medical institutions.

View Article and Find Full Text PDF

Graf ultrasound screening is considered an established method for early detection of developmental dysplasia of the hip (DDH). Although characterized by a high degree of standardization to allow for good reproducibility of results, examination-related factors may still affect sonographic measurements. The relative tilt angle between the hip and the probe is a potential pitfall as it significantly influences sonographic measurements and consequently classification of DDH according to Graf.

View Article and Find Full Text PDF

Patients with cancer expect prolonged life (overall survival, OS) or better life (quality of life, QOL) from cancer treatments. However, majority of new cancer drugs are now being approved not based on improved OS or QOL, but based on surrogate endpoints such as tumor shrinkage or delayed tumor progression. These surrogate endpoints, including their validity as a proxy for overall survival, differ based on disease settings and lines of treatment but in general, most surrogate measures have weak correlation with outcomes that matter to patients.

View Article and Find Full Text PDF

Introduction: Extrapolated reference values (E-Ref) procedure is a new method for determining the cutoff value without collecting the control data. We tried to apply this method to determine the cutoff value for the distal motor latency of the median nerve (median DML). During this process, we found two pitfalls of the E-Ref method.

View Article and Find Full Text PDF

The concept of "blue carbon" is, in this study, critically evaluated with respect to its definitions, measuring approaches, and time scales. Blue carbon deposited in ocean sediments can only counteract anthropogenic greenhouse gas (GHG) emissions if stored on a long-term basis. The focus here is on the coastal blue carbon ecosystems (BCEs), mangrove forests, saltmarshes, and seagrass meadows due to their high primary production and large carbon stocks.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!