Mean flow velocity changes in the middle cerebral arteries (MCAs) during a 2-minute thumb-to-finger opposition task were measured by means of transcranial Doppler ultrasonography in patients with severe unilateral carotid stenosis and ipsilateral transient ischemic attacks and in control subjects. The increase of flow velocity in the MCA contralateral to the hand performing the task was significantly different (p < 0.001, one-way ANOVA) in controls (+5.52 +/- 2.4 cm/sec) and in patients (+1.76 +/- 1.6 cm/sec, side of stenosis; +3.83 +/- 2.1 cm/sec, normal side). A post hoc least significant difference test revealed a significant difference between controls and patients on the side of stenosis (p < 0.001) and between the normal side and the stenotic side in patients (p < 0.03). One month after carotid endarterectomy, the effect of the motor task produced a significantly different effect on flow velocity in patients (p < 0.01, two-way ANOVA) because the increase of flow velocity during the motor task on the side of stenosis (4.84 +/- 1.9 cm/sec) was similar to that observed on the normal side (4.63 +/- 1.4 cm/sec). These findings suggest that the effect of a simple motor task on flow velocity of MCAs may allow for the evaluation of the functional effects of carotid lesions. Prospective studies are needed to evaluate whether this test constitutes a useful approach for the identification of patients who would benefit from a surgical procedure.

Download full-text PDF

Source
http://dx.doi.org/10.1212/wnl.44.10.1910DOI Listing

Publication Analysis

Top Keywords

flow velocity
20
+/- cm/sec
20
side stenosis
12
normal side
12
motor task
12
transcranial doppler
8
functional effects
8
carotid stenosis
8
increase flow
8
side
7

Similar Publications

To what extent sildenafil, a selective inhibitor of the type-5 phosphodiesterase modulates systemic redox status and cerebrovascular function during acute exposure to hypoxia remains unknown. To address this, 12 healthy males (aged 24 ± 3 y) participated in a randomized, placebo-controlled crossover study involving exposure to both normoxia and acute (60 min) hypoxia (Fi = 0.14), followed by oral administration of 50 mg sildenafil and placebo (double-blinded).

View Article and Find Full Text PDF

Aims: To describe the sonographic features of active Charcot neuro-osteoarthropathy (CNO) and assess the potential role of ultrasound in identifying those with active CNO.

Methods: Using a prospective case-series study design we assessed the sonographic features of 14 patients with a diagnosis of diabetes presenting with clinical signs and symptoms suspicious for active CNO. Patients had standard weight-bearing plain X-Ray and, where possible, MRI to evaluate the presence of active CNO.

View Article and Find Full Text PDF

Microneedle(MN)-based drug delivery is one of the potential approaches to overcome the limitations of oral and hypodermic needle delivery. An in silico model has been developed for hollow microneedle (HMN)-based drug delivery in the skin and its subsequent absorption in the blood and tissue compartments in the presence of interstitial flow. The drug's reversible specific saturable binding to its receptors and the kinetics of reversible absorption across the blood and tissue compartments have been taken into account.

View Article and Find Full Text PDF

Metallic injection molding combines aluminum flake metallic pigments with polymers to directly produce components with metallic luster, improving production efficiency and reducing environmental impact. However, flake line defects that occur in regions where ribs or flow paths intersect remain a significant challenge. This study proposes a velocity model that considers the flow characteristics between the surface and core layers and an alignment model that incorporates the orientation of aluminum flakes to predict appearance defects.

View Article and Find Full Text PDF

Water pipelines in water diversion projects can leak, leading to soil deformation and ground subsidence, necessitating research into soil deformation monitoring technology. This study conducted model tests to monitor soil deformation around leaking buried water pipelines using distributed fiber optic strain sensing (DFOSS) technology based on optical frequency domain reflectometry (OFDR). By arranging strain measurement fibers in a pipe-soil model, we investigated how leak location, leak size, pipe burial depth, and water flow velocity affect soil strain field monitoring results.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!