Vascular constriction is said to account for a variety of clinical effects of cocaine. High-resolution 99mTc-hexamethylpropylene amine oxime single photon emission computed tomographic (SPECT) scans, which measure cerebral blood flow, were used to determine whether neonatal brain perfusion deficits are present in newborns with confirmed cocaine exposure. Normal, age-appropriate SPECT scans were found in 21 babies. Conventional neuroimaging was also performed when possible. All but one of the 14 magnetic resonance imaging (MRI) scans and one computed tomographic scan were normal. One MRI showed a mild delay in myelination. All but four neonates had behavioral or electroencephalographic abnormalities, and microcephaly was found in five of 21. The normal neonatal SPECT scans contrast with findings in adult cocaine users, which typically report abnormal findings of cerebral hypoperfusion. This study identifies a unique lack of corresponding cerebral vascular pathology in symptomatic neonates. It raises the possibility that many of these children can escape significant ischemic injury.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/088307389400900311 | DOI Listing |
EJNMMI Phys
January 2025
Institute of Radiology, Nuclear Medicine and Molecular Imaging, Heart and Diabetes Center North Rhine-Westphalia, University Hospital (Ruhr University Bochum), Medical Faculty OWL (Bielefeld University), Bad Oeynhausen, Germany.
Background: The topic of the effect of the patient table on attenuation in myocardial perfusion imaging (MPI) SPECT is gaining new relevance due to deep learning methods. Existing studies on this effect are old, rare and only consider phantom measurements, not patient studies. This study investigates the effect of the patient table on attenuation based on the difference between reconstructions of phantom scans and polar maps of patient studies.
View Article and Find Full Text PDFInt J Comput Assist Radiol Surg
January 2025
Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, USA.
Purpose: Pulmonary perfusion imaging is a key lung health indicator with clinical utility as a diagnostic and treatment planning tool. However, current nuclear medicine modalities face challenges like low spatial resolution and long acquisition times which limit clinical utility to non-emergency settings and often placing extra financial burden on the patient. This study introduces a novel deep learning approach to predict perfusion imaging from non-contrast inhale and exhale computed tomography scans (IE-CT).
View Article and Find Full Text PDFJ Nucl Med
January 2025
Department of Nuclear Medicine, Royal Brisbane and Women's Hospital, Brisbane, Queensland, Australia.
Our aim is to report methodology that has been developed to calibrate and verify PET and SPECT quantitative image accuracy and quality assurance for use with nonstandard radionuclides, especially with longer half-lives, in clinical imaging trials. Procedures have been developed for quantitative PET and SPECT image calibration for use in clinical trials. The protocol uses a 3-step approach: check quantitative accuracy with a previously calibrated radionuclide in a simple geometry, check the novel trial radionuclide in the same geometry, and check the novel radionuclide in a more challenging, complex geometry (the National Electrical Manufacturers Association [NEMA] NU-2 International Electrotechnical Commission [IEC] image-quality phantom).
View Article and Find Full Text PDFCurr Cardiol Rep
January 2025
Onassis Cardiac Surgery Center, Athens, Greece.
Purpose Of Review: Our purpose was to discuss the advantages and disadvantages of various noninvasive imaging modalities in the evaluation of cardiovascular disease (CVD) in patients with autoimmune rheumatic diseases (ARDs). The detailed knowledge of imaging modalities will facilitate the diagnosis and follow up of CVD in ARDs.
Recent Findings: Autoimmune Rheumatic Diseases (ARDs) are characterized by alterations in immunoregulatory system of the body.
J Med Chem
January 2025
Radiopharmaceuticals Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085, India.
In this study, a novel antibody-drug conjugate (ADC) consisting of Rituximab and Chlorambucil (Rituximab-CMB) was synthesized. The average number of drug molecules attached per Rituximab molecule was determined using MALDI-TOF mass spectrometry, revealing a range of 4-6 drug molecules per antibody. To further improve the therapeutic potential of the ADC, it was radiolabeled with the therapeutic radionuclide Lu via a DOTA chelator, achieving a final radiochemical purity of over 95%.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!